Design Criteria
For columns subjected to bending under unfactored dead load, satisfy the minimum reinforcement requirements of Article 5.6.7, using half the exposure factor consistent with the site and other bridge elements.
Evaluate concrete tensile stress at Service I and Service IV for prestressed elements.