Structural Analysis

In lieu of a more detailed analysis, it is permissible to analyze multiple-column caps as simply supported beams on knife-edge supports at the center of piling or columns. If the column is wider than 4 ft., use a model that takes the stiffness of the column into consideration.
Distribute the live load to the beams assuming the slab hinged at each beam except the outside beam.