Materials
Use Class H (HPC) concrete for girder elements:
- Precast Elements:
- Minimum
= 4.0 ksi, Maximum
= 6.0 ksi - Minimum
= 5.0 ksi, Maximum
= 10.0 ksi
- Cast in Place Elements:
- Maximum
= 6.0 ksi
Use Class S concrete for cast in place deck. Use Class S (HPC) if de-icing chemicals are routinely used at the site:
- Maximum
= 4.0 ksi
Use prestressing strand with specified tensile strength,
fpu
of 270 ksi. - Use 0.6 in low-relaxation strands for pretensioning strands.
- Use 0.6 in low-relaxation strands for post-tensioning tendons.
Provide post tension system in accordance with Item 426, “Post-Tensioning” of the
Texas Department of Transportation Standard Specifications for Construction and Maintenance of Highways, Streets, and Bridges, with the following exceptions
:- Non-Severe Corrosive Environments:
- Galvanized or plastic duct can be used
- Meet requirements for Protection Level 1B.
- Do not use tape-sealed connections.
- Severe Corrosive Environments:
- Use plastic duct only
- Meet requirements for Protection Level 2
All stressed tendons in the finished structure must be grouted. All permanent tendons that are stressed at the precast yard must be grouted prior to transport.