LRFD Design

Use the same resistance factors when evaluating conditions with scour at the strength limit state as those used without scour. Do not include the axial resistance of the material lost due to scour in the shaft resistance.
Include on the plans the unfactored resistance to be achieved during construction for the unscoured bridge condition. This resistance will be the minimum target to achieve during dynamic analysis of pile installation.