Lifting Strands
- Recess lifting strands to help prevent corrosion due to exposure to the elements.
- Recess the prestressing strands a minimum 3/4-inch using a torch, grinder, or other approved method. Do not overheat or damage the surrounding concrete.
- Abrade the concrete and the end of the steel strand with a needle gun, steel brush, or other suitable means to ensure that no slag remains on the steel or concrete surfaces.
- Coat the inside of the recessed area, including the strand, with 10 mils (minimum) of neat Type VIII epoxy andrepairthe recess with epoxy mortar.