COUNTY: BEXAR HIGHWAY: FM 1976 LENGTH: 10.3020MI CONTROL NUMBER: 1890-01-046, ETCDBE GOAL: 7.5 % PROJECT NUMBER: STP 2019(111), ETC TYPE: GRAD, BSE, SURF PAV'T MRKINGS TIME FOR COMPLETION: 383 WORKING DAYSGUARANTY: 100,000.00 BIDS RECEIVED UNTIL: 1:00 PM OCTOBER 03, 2018*EST.COST: 16,419,315.10 BIDS WILL BE OPENED: 1:00 PM OCTOBER 03, 2018 MAIL OR DELIVER BIDS TO: FOR PS&E PROJECT QUESTIONS CALL: TEXAS DEPARTMENT OF TRANSPORTATIONEDDIE REYES, PE ATTN: CONSTRUCTION DIVISION - ROOM 1A.2 9320 SE LOOP 410 200 E RIVERSIDESAN ANTONIO, TX 78223 AUSTIN TX 78704-1204210/633-1417 FOR QUESTIONS REGARDING A PROPOSAL CALL 512/416-2498 TO REQUEST A PROPOSAL GO TO http://www.dot.state.tx.us/business/pr.htm FOR ELECTRONIC BIDDING VISIT THE WEBSITE BELOW: http://www.txdot.gov/business/letting-bids/ebs.html ------------------------------------------------------------------------------ COUNTY CONTROL LIMITS FROM HIGHWAY PROJECT LIMITS TO ------------------------------------------------------------------------------ BEXAR1890-01-046WOODLAKE PARKWAY FM 1976STP 2019(111)LP 1604 LENGTH: 5.1510 MILES BEXAR1890-01-050WOODLAKE PARKWAY FM 1976ROW 1890-1-50LP 1604 LENGTH: 5.1510 MILES ------------------------------------------------------------------------------------------------------------- ITEM DESAPPROXIMATE ALT NO. CD. ITEM DESCRIPTIONUNITQUANTITIESBID PRICEAMOUNTSEQ ------------------------------------------------------------------------------------------------------------- 100 6002PREPARING ROWSTA 272.0001 104 6009REMOVING CONC (RIPRAP)SY 1,212.0002 104 6011REMOVING CONC (MEDIANS)SY 480.0003 104 6015REMOVING CONC (SIDEWALKS)SY 1,955.0004 104 6017REMOVING CONC (DRIVEWAYS)SY 3,600.0005 104 6021REMOVING CONC (CURB)LF 14,141.0006 104 6023REMOVING CONC (CTB)LF 180.0007 105 6011REMOVING STAB BASE AND ASPH PAV (2"-6")SY 2,263.0008 105 6030REMOVING STAB BASE & ASPH PAV (8"-14")SY 156,590.0009 110 6001EXCAVATION (ROADWAY)CY 20,497.00010 132 6003EMBANKMENT (FINAL)(ORD COMP)(TY B)CY 18,437.00011 161 6017COMPOST MANUF TOPSOIL (4")SY 156,680.00012 164 6035DRILL SEEDING (PERM) (RURAL) (CLAY)SY 156,680.00013 164 6041DRILL SEEDING (TEMP) (WARM)SY 78,343.00014 164 6043DRILL SEEDING (TEMP) (COOL)SY 78,343.00015 166 6001FERTILIZERAC 32.00016 168 6001VEGETATIVE WATERINGMG 18.00017 169 6002SOIL RETENTION BLANKETS (CL 1) (TY B)SY 156,680.00018 247 6003FL BS (CMP IN PLACE)(TY A GR 3)(IN VEH)CY 35,017.00019 260 6016LIME (HYD, COM, OR QK(SLURRY))TON 2,904.00020 260 6073LIME TRT (SUBGRADE)(8")SY 161,360.00021 310 6009PRIME COAT (MC-30)GAL 31,516.00022 316 6409AGGR (TY-B GR-4)CY 1,499.00023 316 6410ASPH(AC-15P,AC-20-5TR,AC-20XP,AC10-2TR)GAL 49,471.00024 341 6010D-GR HMA TY-B PG70-22TON 47,926.00025 344 6135SUPERPAVE MIXTURES SP-D SAC-A PG76-22TON 17,950.00026 400 6005CEM STABIL BKFLCY 238.00027 400 6008CUT & RESTORE ASPH PAVINGSY 181.00028 401 6001FLOWABLE BACKFILLCY 1,167.00029 402 6001TRENCH EXCAVATION PROTECTIONLF 9,526.00030 416 6032DRILL SHAFT (TRF SIG POLE) (36 IN)LF 156.00031 420 6002CL A CONC (MISC)CY 25.00032 420 6066CL C CONC (RAIL FOUNDATION)CY 18.00033 432 6002RIPRAP (CONC)(5 IN)CY 318.40034 432 6006RIPRAP (CONC)(CL B)CY 137.00035 432 6045RIPRAP (MOW STRIP)(4 IN)CY 175.00036 450 6034RAIL (TY C402)LF 531.00037 462 6006CONC BOX CULV (5 FT X 2 FT)LF 451.00038 462 6015CONC BOX CULV (7 FT X 4 FT)LF 60.00039 462 6051CONC BOX CULV (5 FT X 3 FT)(EXTEND)LF 11.00040 462 6054CONC BOX CULV (6 FT X 3 FT)(EXTEND)LF 28.00041 464 6005RC PIPE (CL III)(24 IN)LF 1,795.00042 464 6032RC PIPE (ARCH)(CL III)(DES 3)LF 484.00043 464 6033RC PIPE (ARCH)(CL III)(DES 4)LF 356.00044 465 6070INLET (COMPL)(PSL)(RC)(3FTX3FT)EA 2.00045 465 6159INLET(COMPL)(PAZD)(FG)(4FTX4FT-3FTX3FT)EA 2.00046 465 6233INLET (COMP) (TY SIDEWALK BRIDGE)EA 2.00047 466 6152WINGWALL (FW - 0) (HW=5 FT)EA 2.00048 466 6153WINGWALL (FW - 0) (HW=6 FT)EA 1.00049 466 6164WINGWALL (FW - S) (HW=3 FT)EA 1.00050 466 6168WINGWALL (FW - S) (HW=7 FT)EA 1.00051 466 6179WINGWALL (PW - 1) (HW=4 FT)EA 1.00052 466 6180WINGWALL (PW - 1) (HW=5 FT)EA 1.00053 466 6181WINGWALL (PW - 1) (HW=6 FT)EA 1.00054 466 6183WINGWALL (PW - 1) (HW=8 FT)EA 2.00055 466 6216WINGWALL (PW) (HW=5 FT) (MOD)EA 1.00056 466 6236WINGWALL (FW-S) (HW=7FT) (MOD)EA 2.00057 467 6395SET (TY II) (24 IN) (RCP) (6: 1) (P)EA 18.00058 467 6545SET (TY II) (DES 3) (RCP) (6: 1) (P)EA 14.00059 467 6555SET (TY II) (DES 4) (RCP) (6: 1) (P)EA 10.00060 479 6002ADJUSTING INLETSEA 10.00061 479 6004ADJUSTING MANHOLES (SANITARY)EA 4.00062 479 6005ADJUSTING MANHOLES (WATER VALVE BOX)EA 8.00063 479 6008ADJUSTING MANHOLES (WATER METER)EA 1.00064 480 6001CLEAN EXIST CULVERTSEA 11.00065 496 6005REMOV STR (WINGWALL)EA 7.00066 496 6007REMOV STR (PIPE)LF 1,575.00067 500 6001MOBILIZATIONLS 1.00068 502 6001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO 25.00069 506 6002ROCK FILTER DAMS (INSTALL) (TY 2)LF 240.00070 506 6011ROCK FILTER DAMS (REMOVE)LF 240.00071 506 6020CONSTRUCTION EXITS (INSTALL) (TY 1)SY 960.00072 506 6024CONSTRUCTION EXITS (REMOVE)SY 960.00073 506 6038TEMP SEDMT CONT FENCE (INSTALL)LF 32,191.00074 506 6039TEMP SEDMT CONT FENCE (REMOVE)LF 32,191.00075 506 6040BIODEG EROSN CONT LOGS (INSTL) (8")LF 658.00076 506 6043BIODEG EROSN CONT LOGS (REMOVE)LF 658.00077 508 6001CONSTRUCTING DETOURSSY 3,363.00078 512 6009PORT CTB (FUR & INST)(LOW PROF)(TY 1)LF 18,720.00079 512 6010PORT CTB (FUR & INST)(LOW PROF)(TY 2)LF 1,280.00080 512 6033PORT CTB (MOVE)(LOW PROF)(TY 1)LF 34,060.00081 512 6034PORT CTB (MOVE)(LOW PROF)(TY 2)LF 2,860.00082 512 6057PORT CTB (REMOVE)(LOW PROF)(TY 1)LF 18,720.00083 512 6058PORT CTB (REMOVE)(LOW PROF)(TY 2)LF 1,280.00084 514 6001PERM CTB (SGL SLOPE) (TY 1) (42 )LF 190.00085 529 6002CONC CURB (TY II)LF 12,928.00086 529 6012CONC CURB (SLOTTED)LF 1,987.00087 529 6020CONC CURB & GUTTER (ARMOR CURB)LF 28.00088 530 6002INTERSECTIONS (ACP)SY 6,057.00089 530 6004DRIVEWAYS (CONC)SY 4,609.00090 530 6005DRIVEWAYS (ACP)SY 2,549.00091 531 6001CONC SIDEWALKS (4")SY 10,179.00092 531 6005CURB RAMPS (TY 2)EA 5.00093 531 6006CURB RAMPS (TY 3)EA 4.00094 531 6010CURB RAMPS (TY 7)EA 25.00095 531 6016CURB RAMPS (TY 21)EA 2.00096 531 6034CURB RAMPS (TY 7)(MOD)EA 2.00097 531 6040CURB RAMPS (TY3)(MOD)EA 2.00098 531 6054CURB RAMPS (TY 21) (MOD)EA 6.00099 536 6004CONC DIRECTIONAL ISLANDSY 441.000100 540 6001MTL W-BEAM GD FEN (TIM POST)LF 2,525.000101 540 6006MTL BEAM GD FEN TRANS (THRIE-BEAM)EA 10.000102 540 6016DOWNSTREAM ANCHOR TERMINAL SECTIONEA 17.000103 540 6020MTL W - BEAM GD FEN (LOW FILL CULVERT)LF 350.000104 542 6001REMOVE METAL BEAM GUARD FENCELF 2,086.000105 542 6002REMOVE TERMINAL ANCHOR SECTIONEA 11.000106 542 6004RM MTL BM GD FENCE TRANS (THRIE-BEAM)EA 2.000107 544 6003GUARDRAIL END TREATMENT (REMOVE)EA 7.000108 544 6006GDRAIL END TRT(INST)(WOOD POST)(TY III)EA 11.000109 560 6001MAILBOX INSTALL-S (TWG-POST) TY 1EA 7.000110 618 6046CONDT (PVC) (SCH 80) (2")LF 660.000111 618 6053CONDT (PVC) (SCH 80) (3")LF 390.000112 618 6058CONDT (PVC) (SCH 80) (4")LF 520.000113 618 6059CONDT (PVC) (SCH 80) (4") (BORE)LF 2,055.000114 620 6009ELEC CONDR (NO.6) BARELF 5,507.000115 620 6010ELEC CONDR (NO.6) INSULATEDLF 1,012.000116 621 6002TRAY CABLE (3 CONDR) (12 AWG)LF 1,167.000117 621 6005TRAY CABLE (4 CONDR) (12 AWG)LF 1,706.000118 624 6009GROUND BOX TY D (162922)EA 5.000119 624 6010GROUND BOX TY D (162922)W/APRONEA 19.000120 625 6002ZINC-COAT STL WIRE STRAND (3/16")LF 3,295.000121 625 6004ZINC-COAT STL WIRE STRAND (5/16")LF 3,295.000122 628 6167ELC SRV TY D 120/240 070(NS)AL(E)TP(O)EA 1.000123 644 6001IN SM RD SN SUP&AM TY10BWG(1)SA(P)EA 81.000124 644 6002IN SM RD SN SUP&AM TY10BWG(1)SA(P-BM)EA 14.000125 644 6004IN SM RD SN SUP&AM TY10BWG(1)SA(T)EA 20.000126 644 6007IN SM RD SN SUP&AM TY10BWG(1)SA(U)EA 4.000127 644 6034IN SM RD SN SUP&AM TYS80(1)SA(U-1EXT)EA 1.000128 644 6037IN SM RD SN SUP&AM TYS80(1)SA(U-WC)EA 17.000129 644 6068RELOCATE SM RD SN SUP&AM TY 10BWGEA 8.000130 644 6076REMOVE SM RD SN SUP&AMEA 127.000131 658 6001INSTL DEL ASSM (D-SW)SZ 1(FLX)GNDEA 13.000132 658 6015INSTL DEL ASSM (D-SW)SZ (BRF)GF1EA 59.000133 658 6038INSTL DEL ASSM (D-DW)SZ 1(FLX)SRFEA 6.000134 662 6004WK ZN PAV MRK NON-REMOV (W)4"(SLD)LF 70,699.000135 662 6012WK ZN PAV MRK NON-REMOV (W)8"(SLD)LF 2,956.000136 662 6016WK ZN PAV MRK NON-REMOV (W)24"(SLD)LF 1,542.000137 662 6017WK ZN PAV MRK NON-REMOV (W)(ARROW)EA 54.000138 662 6029WK ZN PAV MRK NON-REMOV(W)(WORD)EA 10.000139 662 6032WK ZN PAV MRK NON-REMOV (Y)4"(BRK)LF 4,452.000140 662 6034WK ZN PAV MRK NON-REMOV (Y)4"(SLD)LF 69,682.000141 662 6050WK ZN PAV MRK REMOV (REFL) TY II-A-AEA 447.000142 662 6063WK ZN PAV MRK REMOV (W)4"(SLD)LF 3,217.000143 662 6069WK ZN PAV MRK REMOV (W)8"(DOT)LF 193.000144 662 6071WK ZN PAV MRK REMOV (W)8"(SLD)LF 503.000145 662 6095WK ZN PAV MRK REMOV (Y)4"(SLD)LF 5,605.000146 662 6109WK ZN PAV MRK SHT TERM (TAB)TY WEA 2,592.000147 662 6110WK ZN PAV MRK SHT TERM (TAB)TY YEA 1,397.000148 666 6006REFL PAV MRK TY I (W)4"(DOT)(100MIL)LF 30.000149 666 6030REFL PAV MRK TY I (W)8"(DOT)(100MIL)LF 195.000150 666 6036REFL PAV MRK TY I (W)8"(SLD)(100MIL)LF 7,040.000151 666 6042REFL PAV MRK TY I (W)12"(SLD)(100MIL)LF 235.000152 666 6048REFL PAV MRK TY I (W)24"(SLD)(100MIL)LF 3,537.000153 666 6054REFL PAV MRK TY I (W)(ARROW)(100MIL)EA 48.000154 666 6057REFL PAV MRK TY I(W)(DBL ARROW)(100MIL)EA 1.000155 666 6078REFL PAV MRK TY I (W)(WORD)(100MIL)EA 48.000156 666 6093REFL PAV MRK TY I (W)(RR XING)(100MIL)EA 2.000157 666 6099REF PAV MRK TY I(W)18"(YLD TRI)(100MIL)EA 97.000158 666 6147REFL PAV MRK TY I (Y)24"(SLD)(100MIL)LF 60.000159 666 6156REFL PAV MRK TY I(Y)(MED NOSE)(100MIL)EA 7.000160 666 6224PAVEMENT SEALER 4"LF 75,355.000161 666 6225PAVEMENT SEALER 6"LF 46,940.000162 666 6226PAVEMENT SEALER 8"LF 7,235.000163 666 6228PAVEMENT SEALER 12"LF 235.000164 666 6230PAVEMENT SEALER 24"LF 3,597.000165 666 6231PAVEMENT SEALER (ARROW)EA 48.000166 666 6232PAVEMENT SEALER (WORD)EA 48.000167 666 6233PAVEMENT SEALER (MED NOSE)EA 7.000168 666 6234PAVEMENT SEALER (DBL ARROW)EA 1.000169 666 6242PAVEMENT SEALER (RR XING)EA 2.000170 666 6243PAVEMENT SEALER (YLD TRI)EA 97.000171 666 6300RE PM W/RET REQ TY I (W)4"(BRK)(100MIL)LF 6,640.000172 666 6303RE PM W/RET REQ TY I (W)4"(SLD)(100MIL)LF 555.000173 666 6312RE PM W/RET REQ TY I (Y)4"(BRK)(100MIL)LF 3,340.000174 666 6315RE PM W/RET REQ TY I (Y)4"(SLD)(100MIL)LF 64,790.000175 666 6343REF PROF PAV MRK TY I(W)6"(SLD)(100MIL)LF 46,940.000176 672 6007REFL PAV MRKR TY I-CEA 751.000177 672 6009REFL PAV MRKR TY II-A-AEA 2,217.000178 677 6001ELIM EXT PAV MRK & MRKS (4")LF 9,635.000179 677 6007ELIM EXT PAV MRK & MRKS (24")LF 60.000180 680 6002INSTALL HWY TRF SIG (ISOLATED)EA 9.000181 680 6004REMOVING TRAFFIC SIGNALSEA 8.000182 681 6001TEMP TRAF SIGNALSEA 7.000183 682 6001VEH SIG SEC (12")LED(GRN)EA 48.000184 682 6002VEH SIG SEC (12")LED(GRN ARW)EA 28.000185 682 6003VEH SIG SEC (12")LED(YEL)EA 52.000186 682 6004VEH SIG SEC (12")LED(YEL ARW)EA 40.000187 682 6005VEH SIG SEC (12")LED(RED)EA 50.000188 682 6006VEH SIG SEC (12")LED(RED ARW)EA 23.000189 682 6018PED SIG SEC (LED)(COUNTDOWN)EA 18.000190 682 6021BACK PLATE (12")(1 SEC)EA 6.000191 682 6023BACK PLATE (12")(3 SEC)EA 50.000192 682 6024BACK PLATE (12")(4 SEC)EA 20.000193 682 6025BACK PLATE (12")(5 SEC)EA 1.000194 684 6009TRF SIG CBL (TY A)(12 AWG)(4 CONDR)LF 4,879.000195 684 6012TRF SIG CBL (TY A)(12 AWG)(7 CONDR)LF 9,966.000196 684 6035TRF SIG CBL (TY A)(14 AWG)(9 CONDR)LF 2,173.000197 684 6049TRF SIG CBL (TY A)(16 AWG)(3 CONDR)LF 1,304.000198 684 6080TRF SIG CBL (TY C)(14 AWG)(2 CONDR)LF 3,619.000199 686 6019INS TRF SIG PL AM (S)STR(TY D)EA 4.000200 686 6020INS TRF SIG PL AM (S)STR(TY D)LUMEA 4.000201 686 6282RELOC TRF SG PL AM(S)SNGL MST ARM POLEEA 2.000202 687 6001PED POLE ASSEMBLYEA 18.000203 688 6001PED DETECT PUSH BUTTON (APS)EA 26.000204 688 6003PED DETECTOR CONTROLLER UNITEA 5.000205 690 6068REPLACE OF LUMINAIRE MAST ARMSEA 10.000206 730 6003SPOT MOWINGAC 50.000207 734 6002LITTER REMOVALCYC 12.000208 60016002PORTABLE CHANGEABLE MESSAGE SIGNEA 23.000209 60026007VIVDS TEMPORARYEA 6.000210 60256001RADAR PRESENCE DETECTOREA 26.000211 60256002RADAR PRESENCE DETECTOR COMM CABLELF 5,526.000212 60496001LONG CHANNEL MOUNT CURB SYS (INSTALL)LF 300.000213 60576001RADAR ADVANCED DETECTION DEVICEEA 15.000214 61856002TMA (STATIONARY)DAY 499.000215 71846001TRENCH EXCAVATION PROTECTIONLF 1,078.000216 71846002DUCTILE IRON FITTINGSTON 1.600217 71846003HYDROSTATIC PRESSURE TESTEA 2.000218 71846004TEMPORARY BLOW-OFF(COMPLETE)(2")EA 3.000219 71846005FLOWABLE FILL BACKFILLCY 45.000220 71846006PIPE WATER MAIN (PVC)(8")LF 10.000221 71846009TIE-IN (COMPLETE)(8")EA 1.000222 71846011ADJUST VALVE BOXEA 22.000223 71846019RELAY SHORT SERVICE (3/4")LF 1.000224 71846032NEW METER BOXEA 9.000225 71846033FIRE HYDRANT ASSEMBLYEA 1.000226 71846036TIE-IN (COMPLETE)(12")EA 2.000227 71846042PIPE WATER MAIN (PVC) (12")LF 920.000228 71846043GATE VALVE AND BOX (COMPLETE) (12")EA 4.000229 71846044RELOC EXIST METER AND EXIST METER BOXEA 10.000230 71846045RELOCATE FIRE HYDRANTEA 9.000231 71846046PERMANENT BLOW-OFF (COMPLETE) (2")EA 1.000232 71846047WATER SERVICE LINE BREAKS LEAK REPAIREA 1.000233 71846048WATER MAIN BREAKS LEAK REPAIREA 1.000234 71846049STEEL CASING (24") (OPEN CUT)LF 148.000235 71846050CARRIER PIPE (OPEN CUT) (PVC) (12")LF 148.000236 71846051GROUT ABANDONMENT WATER MAIN (12")LF 80.000237 71866002NGP (MAIN) (8" PLASTIC W/ TW)LF 6,742.000238 71866003NGP (MAIN) (6" PLASTIC W/TW) (OPEN CUT)LF 358.000239 71866004NGP (MAIN) (4" PLASTIC W/TW) (OPEN CUT)LF 1,029.000240 71866005NGP (SHORT SVC) (NEW MAIN TO PROP LINE)EA 5.000241 71906001GROUT ABANDONMENT SWR MAIN (12IN)LF 308.000242 71906002GROUT ABANDONMENT SWR MAIN (15IN)LF 115.000243 71906003SAN SWR ABANDON 4 FT DIA MHEA 3.000244 71906004SAN SWR ADJUST MANHOLEEA 11.000245 71906005SAN SWR BYPASS PUMPINGLS 1.000246 71906006SAN SWR CONCRETE ENCASEMENTCY 16.000247 71906007SAN SWR CPS POWER POLE BRACINGEA 5.000248 71906008SAN SWR MANHOLE (EXTRA DEPTH)LF 24.000249 71906009SAN SWR FLOWABLE BACKFILLCY 1,996.000250 71906010SAN SWR INSTALL 12" PVC CARR PIPELF 385.000251 71906011SAN SWR INSTALL 12" PVC PIPELF 1,640.000252 71906012SAN SWR INSTALL 18" PVC CARR PIPELF 190.000253 71906013SAN SWR INSTALL 18" PVC PIPELF 60.000254 71906015SAN SWR INSTALL 24" CASING OPEN CUTLF 385.000255 71906016SAN SWR INSTALL 24" PVC CARR PIPELF 172.000256 71906018SAN SWR INSTALL 36" CASING OPEN CUTLF 190.000257 71906019SAN SWR INSTALL 4 FT DIA MHEA 8.000258 71906020SAN SWR INSTALL 48" CASING OPEN CUTLF 172.000259 71906021SAN SWR (MH REHAB)(4FT DIA)EA 17.000260 71906022REMOVE EXISTING MANHOLE (SAN SWR)EA 2.000261 71906023GROUT ABANDONMENT SWR MAIN (20IN)LF 5.000262 * INCLUDES FORCE ACCOUNT WORK AMOUNTS AS FOLLOWS: CONTRACTOR FORCE ACCOUNT WORK (PART) $74,737.10