COUNTY: HARRIS HIGHWAY: CS LENGTH: 2.0470MI CONTROL NUMBER: 0912-72-075 DBE GOAL: 7.5 % PROJECT NUMBER: HP 1402(016) TYPE: RECONSTRUCT CLINTON DRIVE TIME FOR COMPLETION: 475 WORKING DAYSGUARANTY: 100,000.00 BIDS RECEIVED UNTIL: 1:00 PM JULY 10, 2018*EST.COST: 22,397,920.27 BIDS WILL BE OPENED: 1:00 PM JULY 10, 2018 MAIL OR DELIVER BIDS TO: FOR PS&E PROJECT QUESTIONS CALL: TEXAS DEPARTMENT OF TRANSPORTATIONMELODY GALLAND ATTN: CONSTRUCTION DIVISION - ROOM 1A.2 702 FM 1959 200 E RIVERSIDEHOUSTON, TX 77034 AUSTIN TX 78704-1204281/464-5500 FOR QUESTIONS REGARDING A PROPOSAL CALL 512/416-2498 TO REQUEST A PROPOSAL GO TO http://www.dot.state.tx.us/business/pr.htm FOR ELECTRONIC BIDDING VISIT THE WEBSITE BELOW: http://www.txdot.gov/business/letting-bids/ebs.html LIMITS FROM: CLINTON DR-PORT OF HOUSTON GATE 8 LIMITS TO: IH 610 ------------------------------------------------------------------------------------------------------------- ITEM DESAPPROXIMATE ALT NO. CD. ITEM DESCRIPTIONUNITQUANTITIESBID PRICEAMOUNTSEQ ------------------------------------------------------------------------------------------------------------- 100 6002PREPARING ROWSTA 108.0001 100 6003PREPARING ROW(TREE)(5" TO 12" DIA)EA 27.0002 100 6004PREPARING ROW(TREE)(12" TO 24" DIA)EA 28.0003 100 6007PREP ROW (TREE)(GREATER THAN 24" DIA)EA 14.0004 104 6001REMOVING CONC (PAV)SY 67,236.0005 104 6009REMOVING CONC (RIPRAP)SY 1,518.0006 104 6017REMOVING CONC (DRIVEWAYS)SY 2,039.0007 104 6021REMOVING CONC (CURB)LF 3,466.0008 105 6037REMOVING STAB BASE AND ASPH PAV(0"-16")SY 67,236.0009 110 6001EXCAVATION (ROADWAY)CY 69,853.00010 132 6003EMBANKMENT (FINAL)(ORD COMP)(TY B)CY 144.00011 132 6006EMBANKMENT (FINAL)(DENS CONT)(TY C)CY 6,049.00012 161 6017COMPOST MANUF TOPSOIL (4")SY 15,591.00013 162 6002BLOCK SODDINGSY 23,259.00014 162 6003STRAW OR HAY MULCHSY 23,472.00015 164 6037DRILL SEEDING (PERM) (URBAN) (SANDY)SY 15,591.00016 164 6051DRILL SEED (TEMP)(WARM OR COOL)SY 7,881.00017 166 6001FERTILIZERAC 9.66018 168 6001VEGETATIVE WATERINGMG 1,158.62019 260 6006LIME TRT (EXST MATL) (6")SY 89,438.00020 260 6012LIME(HYD,COM OR QK)(SLRY)OR QK(DRY)TON 1,408.60021 276 6224CEM TRT(PLNT MX) (CL N)(TY E)(GR 4)(6")SY 88,891.00022 292 6002ASPHALT STAB BASE (GR 2)(PG 64)TON 518.10023 292 6017ASPHALT STAB BASE (GR 4)(PG 64)TON 4,918.80024 341 6049D-GR HMA TY-D PG76-22TON 77.70025 341 6062D-GR HMA TY-D PG64-22(LEVEL-UP)TON 77.70026 360 6006CONC PVMT (CONT REINF - CRCP) (12")SY 68,697.00027 360 6043CONC PVMT (CONT REINF)(FAST TRK)(13")SY 9,200.00028 361 6047FULL - DEPTH REPAIR CPJR (12")SY 512.00029 400 6005CEM STABIL BKFLCY 18,617.03030 400 6007CUT & RESTORE CONC PAVINGSY 109.00031 400 6009CEMENT STAB BACKFILL (INLET OR MH)CY 2,119.75032 402 6001TRENCH EXCAVATION PROTECTIONLF 40,214.80033 403 6001TEMPORARY SPL SHORINGSF 71,220.00034 416 6006DRILL SHAFT (48 IN)LF 1,776.00035 416 6031DRILL SHAFT (TRF SIG POLE) (30 IN)LF 78.00036 416 6032DRILL SHAFT (TRF SIG POLE) (36 IN)LF 28.00037 420 6054CL C CONC (HEADWALL)CY 64.00038 420 6057CL C CONC (WINGWALLS)CY 4.00039 420 6074CL C CONC (MISC)CY 2.00040 423 6007RETAINING WALL (DRILL SHAFT) (FACIA)SF 1,747.00041 432 6002RIPRAP (CONC)(5 IN)CY 61.90042 432 6007RIPRAP (CONC)(CL C)CY 251.00043 432 6009RIPRAP (CONC) (CL B) (4")CY 8.20044 432 6045RIPRAP (MOW STRIP)(4 IN)CY 8.10045 450 6070RAIL (TY PR2) (MOD)LF 98.00046 460 6005CMP (GAL STL 36 IN)LF 15.00047 462 6007CONC BOX CULV (5 FT X 3 FT)LF 894.00048 464 6005RC PIPE (CL III)(24 IN)LF 4,301.00049 464 6007RC PIPE (CL III)(30 IN)LF 716.00050 464 6008RC PIPE (CL III)(36 IN)LF 1,570.00051 464 6009RC PIPE (CL III)(42 IN)LF 1,317.00052 464 6011RC PIPE (CL III)(54 IN)LF 45.00053 464 6012RC PIPE (CL III)(60 IN)LF 1,762.00054 464 6013RC PIPE (CL III)(66 IN)LF 1,482.00055 464 6032RC PIPE (ARCH)(CL III)(DES 3)LF 439.00056 464 6077RC PIPE (CL III)(78 IN)LF 3,157.00057 465 6173MANH (COMPL)(TY A)EA 27.00058 465 6174MANH (COMPL)(TY B)EA 24.00059 465 6175INLET (COMPL)(CURB)(TY C)EA 48.00060 465 6176INLET (COMPL)(CURB)(TY C1)EA 35.00061 465 6251INLET(COMPL)(EXT)(TY E)EA 111.00062 465 6275MANH (COMPL)(JUNCT BOX)EA 4.00063 467 6395SET (TY II) (24 IN) (RCP) (6: 1) (P)EA 25.00064 467 6449SET (TY II) (36 IN) (RCP) (3: 1) (P)EA 1.00065 471 6003GRATE & FRAMEEA 3.00066 476 6029JACK BOR OR TUN PIPE(42 IN)(RC)(CL III)LF 150.00067 476 6075JACK BOR TUN BOX CULV(5FTX3FT)E-80 COOPLF 240.00068 476 6106JACK BOR TUN BOX CULV(6FTX5FT)E-80 COOPLF 192.00069 496 6002REMOV STR (INLET)EA 12.00070 496 6003REMOV STR (MANHOLE)EA 29.00071 496 6007REMOV STR (PIPE)LF 1,168.00072 500 6001MOBILIZATIONLS 1.00073 502 6001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO 32.00074 506 6020CONSTRUCTION EXITS (INSTALL) (TY 1)SY 200.00075 506 6024CONSTRUCTION EXITS (REMOVE)SY 200.00076 506 6034CONSTRUCTION PERIMETER FENCELF 20,194.00077 506 6038TEMP SEDMT CONT FENCE (INSTALL)LF 20,194.00078 506 6039TEMP SEDMT CONT FENCE (REMOVE)LF 20,194.00079 506 6047TEMP SDMT CONT FENCE (INLET PROTECTION)LF 3,866.00080 508 6001CONSTRUCTING DETOURSSY 3,412.00081 512 6021PORT CTB (DES SOURCE)(LOW PROF)(TY 1)LF 10,180.00082 512 6022PORT CTB (DES SOURCE)(LOW PROF)(TY 2)LF 80.00083 512 6045PORT CTB (STKPL)(LOW PROF)(TY 1)LF 10,180.00084 512 6046PORT CTB (STKPL)(LOW PROF)(TY 2)LF 80.00085 512 6080PORT CTB CONNECT HARDWAREEA 262.00086 529 6002CONC CURB (TY II)LF 751.00087 529 6005CONC CURB (MONO) (TY II)LF 37,079.00088 530 6004DRIVEWAYS (CONC)SY 2,916.00089 531 6002CONC SIDEWALKS (5")SY 10,088.00090 531 6008CURB RAMPS (TY 5)EA 1.00091 531 6010CURB RAMPS (TY 7)EA 20.00092 550 6001CHAIN LINK FENCE (INSTALL) (6')LF 2,268.00093 550 6003CHAIN LINK FENCE (REMOVE)LF 40.00094 550 6008CHAIN LINK FENCE (INSTALL) (8')LF 258.00095 618 6023CONDT (PVC) (SCH 40) (2")LF 10,123.00096 618 6033CONDT (PVC) (SCH 40) (4")LF 9,953.00097 618 6034CONDT (PVC) (SCH 40) (4") (BORE)LF 170.00098 618 6040CONDT (PVC) (SCH 80) (1")LF 930.00099 618 6046CONDT (PVC) (SCH 80) (2")LF 2,710.000100 618 6053CONDT (PVC) (SCH 80) (3")LF 390.000101 618 6058CONDT (PVC) (SCH 80) (4")LF 75.000102 618 6070CONDT (RM) (2")LF 140.000103 618 6074CONDT (RM) (3")LF 140.000104 620 6009ELEC CONDR (NO.6) BARELF 930.000105 620 6012ELEC CONDR (NO.4) INSULATEDLF 230.000106 621 6005TRAY CABLE (4 CONDR) (12 AWG)LF 780.000107 624 6002GROUND BOX TY A (122311)W/APRONEA 1.000108 624 6007GROUND BOX TY C (162911)EA 27.000109 624 6010GROUND BOX TY D (162922)W/APRONEA 27.000110 628 6002REMOVE ELECTRICAL SERVICESEA 2.000111 628 6188ELC SRV TY D 120/240 070(NS)SS(E)SP(O)EA 2.000112 644 6001IN SM RD SN SUP&AM TY10BWG(1)SA(P)EA 28.000113 644 6002IN SM RD SN SUP&AM TY10BWG(1)SA(P-BM)EA 5.000114 644 6004IN SM RD SN SUP&AM TY10BWG(1)SA(T)EA 2.000115 644 6007IN SM RD SN SUP&AM TY10BWG(1)SA(U)EA 1.000116 644 6027IN SM RD SN SUP&AM TYS80(1)SA(P)EA 2.000117 644 6030IN SM RD SN SUP&AM TYS80(1)SA(T)EA 2.000118 644 6031IN SM RD SN SUP&AM TYS80(1)SA(T-2EXT)EA 1.000119 644 6068RELOCATE SM RD SN SUP&AM TY 10BWGEA 8.000120 644 6070RELOCATE SM RD SN SUP&AM TY S80EA 1.000121 662 6004WK ZN PAV MRK NON-REMOV (W)4"(SLD)LF 2,067.000122 662 6034WK ZN PAV MRK NON-REMOV (Y)4"(SLD)LF 42,452.000123 662 6063WK ZN PAV MRK REMOV (W)4"(SLD)LF 2,847.000124 662 6075WK ZN PAV MRK REMOV (W)24"(SLD)LF 120.000125 662 6095WK ZN PAV MRK REMOV (Y)4"(SLD)LF 20,740.000126 666 6006REFL PAV MRK TY I (W)4"(DOT)(100MIL)LF 197.000127 666 6036REFL PAV MRK TY I (W)8"(SLD)(100MIL)LF 3,050.000128 666 6042REFL PAV MRK TY I (W)12"(SLD)(100MIL)LF 1,403.000129 666 6048REFL PAV MRK TY I (W)24"(SLD)(100MIL)LF 816.000130 666 6054REFL PAV MRK TY I (W)(ARROW)(100MIL)EA 35.000131 666 6078REFL PAV MRK TY I (W)(WORD)(100MIL)EA 32.000132 666 6093REFL PAV MRK TY I (W)(RR XING)(100MIL)EA 8.000133 666 6147REFL PAV MRK TY I (Y)24"(SLD)(100MIL)LF 1,325.000134 666 6156REFL PAV MRK TY I(Y)(MED NOSE)(100MIL)EA 41.000135 666 6167REFL PAV MRK TY II (W) 4" (BRK)LF 4,710.000136 666 6168REFL PAV MRK TY II (W) 4" (DOT)LF 197.000137 666 6170REFL PAV MRK TY II (W) 4" (SLD)LF 160.000138 666 6178REFL PAV MRK TY II (W) 8" (SLD)LF 3,050.000139 666 6180REFL PAV MRK TY II (W) 12" (SLD)LF 1,403.000140 666 6182REFL PAV MRK TY II (W) 24" (SLD)LF 816.000141 666 6184REFL PAV MRK TY II (W) (ARROW)EA 35.000142 666 6192REFL PAV MRK TY II (W) (WORD)EA 32.000143 666 6196REFL PAV MRK TY II (W) (RR XING)EA 8.000144 666 6207REFL PAV MRK TY II (Y) 4" (SLD)LF 4,989.000145 666 6212REFL PAV MRK TY II (Y) 12" (SLD)LF 6,556.000146 666 6214REFL PAV MRK TY II (Y) 24" (SLD)LF 1,325.000147 666 6217REFL PAV MRK TY II (Y) (MED NOSE)EA 41.000148 666 6300RE PM W/RET REQ TY I (W)4"(BRK)(100MIL)LF 4,710.000149 666 6303RE PM W/RET REQ TY I (W)4"(SLD)(100MIL)LF 160.000150 666 6315RE PM W/RET REQ TY I (Y)4"(SLD)(100MIL)LF 4,989.000151 672 6007REFL PAV MRKR TY I-CEA 30.000152 672 6009REFL PAV MRKR TY II-A-AEA 181.000153 672 6010REFL PAV MRKR TY II-C-REA 591.000154 678 6001PAV SURF PREP FOR MRK (4")LF 10,056.000155 678 6004PAV SURF PREP FOR MRK (8")LF 3,050.000156 678 6006PAV SURF PREP FOR MRK (12")LF 7,959.000157 678 6008PAV SURF PREP FOR MRK (24")LF 2,141.000158 678 6009PAV SURF PREP FOR MRK (ARROW)EA 35.000159 678 6016PAV SURF PREP FOR MRK (WORD)EA 32.000160 678 6020PAV SURF PREP FOR MRK (RR XING)EA 8.000161 678 6024PAV SURF PREP FOR MRK (MED NOSE)EA 41.000162 680 6003INSTALL HWY TRF SIG (SYSTEM)EA 2.000163 680 6004REMOVING TRAFFIC SIGNALSEA 2.000164 681 6001TEMP TRAF SIGNALSEA 3.000165 682 6001VEH SIG SEC (12")LED(GRN)EA 14.000166 682 6002VEH SIG SEC (12")LED(GRN ARW)EA 6.000167 682 6003VEH SIG SEC (12")LED(YEL)EA 14.000168 682 6004VEH SIG SEC (12")LED(YEL ARW)EA 6.000169 682 6005VEH SIG SEC (12")LED(RED)EA 14.000170 682 6006VEH SIG SEC (12")LED(RED ARW)EA 6.000171 682 6018PED SIG SEC (LED)(COUNTDOWN)EA 10.000172 682 6023BACK PLATE (12")(3 SEC)EA 20.000173 684 6015TRF SIG CBL (TY A)(12 AWG)(10 CONDR)LF 140.000174 684 6029TRF SIG CBL (TY A)(14 AWG)(3 CONDR)LF 1,060.000175 684 6031TRF SIG CBL (TY A)(14 AWG)(5 CONDR)LF 1,060.000176 684 6033TRF SIG CBL (TY A)(14 AWG)(7 CONDR)LF 4,860.000177 684 6080TRF SIG CBL (TY C)(14 AWG)(2 CONDR)LF 4,650.000178 686 6304INS TRF PL AM HOU-1-25EA 1.000179 686 6305INS TRF PL AM HOU-1-25(LUM)EA 1.000180 686 6306INS TRF PL AM HOU-1-35(LUM)EA 1.000181 686 6307INS TRF PL AM HOU-2-40(LUM)EA 1.000182 686 6308INS TRF PL AM(1) ARM (44')(HINGED)EA 1.000183 686 6309INS TRF PL AM(1) ARM (44')(LUM)(HNGD)EA 1.000184 686 6310INS TRF PL AM HOU-2-45EA 1.000185 687 6001PED POLE ASSEMBLYEA 5.000186 688 6001PED DETECT PUSH BUTTON (APS)EA 10.000187 688 6004VEH LP DETECT (SAWCUT)LF 1,495.000188 730 6107FULL - WIDTH MOWINGCYC 8.000189 734 6002LITTER REMOVALCYC 8.000190 735 6003DEBRIS REMOVAL (FRONTAGE ROADS)CYC 8.000191 738 6005CLEANING / SWEEPING (FRONTAGE ROAD)CYC 32.000192 60016001PORTABLE CHANGEABLE MESSAGE SIGNDAY 70.000193 60026007VIVDS TEMPORARYEA 2.000194 60586001BBU SYSTEM (EXTERNAL BATT CABINET)EA 2.000195 60616001GPS COMMUNICATIONS UNITEA 2.000196 70176005SANITARY SEWER (8IN) (PVC) (C900)LF 1,106.000197 70176051MANHOLE (SAN SEWER) ( 4' DIA)EA 7.000198 70176055ADJUSTING MANHOLE (SANITARY SEWER)EA 4.000199 70176057JACK BOR OR TUN(SANSWR)(PVC)(6IN)(C900)LF 240.000200 70176073SERVICE CONNECTION (SANITARY SEWER)EA 14.000201 70176077ABANDON SANITARY SEWER (8IN)EA 5.000202 70176089AUTOMATIC AIR RELEASE VALVE W / CONC MHEA 7.000203 70176091FM CONNECTION (FORCE MAIN)EA 2.000204 70176100CUT & CAP ABND SANITARY SEWER MHEA 6.000205 70176119SAN SEWER(FM)(PVC)(C900)(DR 18)(RJ)6 INLF 565.000206 70176120SAN SEWER(FM)(PVC)(C900)(DR 18)(6 IN)LF 5,942.000207 70496004WATER MAIN PIPE (PVC) (6IN)LF 63.000208 70496005WATER MAIN PIPE (PVC) (8IN)LF 2,615.000209 70496007WATER MAIN PIPE (PVC) (12IN)LF 1,394.000210 70496020WTR MAIN PIPE (PVC)(RESTRAINED JT) 8INLF 600.000211 70496021WTR MAIN PIPE (PVC)(RESTRAINED JT) 12INLF 529.000212 70496050CASING STEEL (36IN)LF 100.000213 70496052FIRE HYDRANT BRANCH (LEAD) (6IN)LF 273.000214 70496057JCK TUN BOR OR AUG WTR MAIN (PVC)(12INLF 210.000215 70496075SERVICE LINE (LONG SIDE) (5/8" TO 1")EA 6.000216 70496077SERVICE LINE (LONG SIDE) (1-1/2"TO 2")EA 1.000217 70496087TAPPING SLEEVE AND VALVE (12IN X 6IN)EA 9.000218 70496104FIRE HYDRANT ASSEMBLYEA 23.000219 70496105WATER METER AND VAULTEA 1.000220 70496117REMOVE WATER METER AND VAULTEA 1.000221 70496119REMOVING AND SALVAGING FIRE HYDRANTEA 16.000222 70496126CUT AND PLUG WATER MAIN (6IN)EA 17.000223 70496127CUT AND PLUG WATER MAIN (8IN)EA 34.000224 70496129CUT AND PLUG WATER MAIN (12IN)EA 16.000225 70496139WET CONNECTION (6IN)EA 1.000226 70496140WET CONNECTION (8IN)EA 1.000227 70496142WET CONNECTION (12IN)EA 7.000228 70496149WATER MAIN (ADJ EXIST MANHOLE)EA 28.000229 70496177SPLIT STEEL CASING(18IN)LF 30.000230 70496178CUT AND PLUG WATER MAIN (36IN)EA 8.000231 70496179ASBESTOS ABATEMENT SUPT & COORDINATIONLS 1.000232 70496180REMOV AIR/VAC VAULTEA 3.000233 70496181REMOV & REPLAC VENT ASSEMBLYEA 10.000234 70496182EXIST AIR/VAC MODIFICATIONEA 1.000235 70496183AIR RELEASE/VACUUM RELEASE VAULTEA 3.000236 70496184CATHODIC PROTECTIONLS 1.000237 * INCLUDES FORCE ACCOUNT WORK AMOUNTS AS FOLLOWS: CONTRACTOR FORCE ACCOUNT WORK $47,704.00 RAILROAD FORCE ACCOUNT WORK (PART) $383,100.00 RAILROAD FORCE ACCOUNT WORK (PART) $383,100.00