COUNTY: BASTROP HIGHWAY: SH 95 LENGTH: 0.5520MI CONTROL NUMBER: 0322-01-051 DBE GOAL: 4.0 % PROJECT NUMBER: STP 2020(964)HES TYPE: SAFETY IMPROVEMENT PROJECTS TIME FOR COMPLETION: 118 WORKING DAYSGUARANTY: 37,000.00 BIDS RECEIVED UNTIL: 1:00 PM JUNE 05, 2020*EST.COST: 1,855,085.10 BIDS WILL BE OPENED: 1:00 PM JUNE 05, 2020 MAIL OR DELIVER BIDS TO: FOR PS&E PROJECT QUESTIONS CALL: TEXAS DEPARTMENT OF TRANSPORTATIONDIANA SCHULZE ATTN: CONSTRUCTION DIVISION - ROOM 1A.2 174 SH 21 EAST 200 E RIVERSIDEBASTROP, TX 78602 AUSTIN TX 78704-1204512/308-4468 FOR QUESTIONS REGARDING A PROPOSAL CALL 512/416-2498 TO REQUEST A PROPOSAL GO TO http://www.dot.state.tx.us/business/pr.htm FOR ELECTRONIC BIDDING VISIT THE WEBSITE BELOW: http://www.txdot.gov/business/letting-bids/ebs.html LIMITS FROM: 0.304 MI. NORTH OF LBA DRIVE LIMITS TO: 0.236 MI. SOUTH OF LBA DRIVE ------------------------------------------------------------------------------------------------------------- ITEM DESAPPROXIMATE ALT NO. CD. ITEM DESCRIPTIONUNITQUANTITIESBID PRICEAMOUNTSEQ ------------------------------------------------------------------------------------------------------------- 100 6002PREPARING ROWSTA 23.9301 104 6009REMOVING CONC (RIPRAP)SY 1,127.0002 104 6017REMOVING CONC (DRIVEWAYS)SY 91.0003 105 6085REMOVING STAB BASE & ASPH PAV (0-19 IN)SY 532.0004 110 6001EXCAVATION (ROADWAY)CY 1,699.0005 132 6003EMBANKMENT (FINAL)(ORD COMP)(TY B)CY 1,395.0006 160 6003FURNISHING AND PLACING TOPSOIL (4")SY 3,489.0007 164 6009BROADCAST SEED (TEMP) (WARM)SY 1,745.0008 164 6011BROADCAST SEED (TEMP) (COOL)SY 1,745.0009 164 6035DRILL SEEDING (PERM) (RURAL) (CLAY)SY 3,489.00010 168 6001VEGETATIVE WATERINGMG 29.00011 247 6366FL BS (CMP IN PLC)(TY A GR 5)(FNAL POS)CY 1,185.00012 310 6001PRIME COAT (MULTI OPTION)GAL 834.00013 347 6001TOM (ASPHALT) PG 76-22TON 57.00014 347 6006TOM - C (AGGREGATE) SAC - BTON 869.00015 400 6001STRUCT EXCAVCY 11.00016 400 6005CEM STABIL BKFLCY 8.00017 402 6001TRENCH EXCAVATION PROTECTIONLF 2.00018 403 6001TEMPORARY SPL SHORINGSF 6,668.00019 416 6030DRILL SHAFT (TRF SIG POLE) (24 IN)LF 11.40020 416 6031DRILL SHAFT (TRF SIG POLE) (30 IN)LF 11.30021 416 6032DRILL SHAFT (TRF SIG POLE) (36 IN)LF 26.40022 423 6008RETAINING WALL (CAST - IN - PLACE)SF 6,668.00023 432 6001RIPRAP (CONC)(4 IN)CY 49.00024 432 6002RIPRAP (CONC)(5 IN)CY 211.00025 432 6045RIPRAP (MOW STRIP)(4 IN)CY 28.00026 432 6051RIPRAP (STONE COMMON)(GROUT)(18 IN)CY 25.00027 462 6049CONC BOX CULV (4 FT X 4 FT)(EXTEND)LF 2.00028 464 6003RC PIPE (CL III)(18 IN)LF 256.00029 464 6005RC PIPE (CL III)(24 IN)LF 12.00030 466 6214HEADWALL (CH - PW - 0)(DIA= 24 IN)(MOD)EA 1.00031 467 6363SET (TY II) (18 IN) (RCP) (6: 1) (P)EA 8.00032 496 6004REMOV STR (SET)EA 6.00033 496 6005REMOV STR (WINGWALL)EA 3.00034 496 6007REMOV STR (PIPE)LF 199.00035 500 6001MOBILIZATIONLS 1.00036 502 6001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO 8.00037 506 6002ROCK FILTER DAMS (INSTALL) (TY 2)LF 200.00038 506 6011ROCK FILTER DAMS (REMOVE)LF 200.00039 506 6038TEMP SEDMT CONT FENCE (INSTALL)LF 3,038.00040 506 6039TEMP SEDMT CONT FENCE (REMOVE)LF 3,038.00041 512 6001PORT CTB (FUR & INST)(SGL SLOPE)(TY 1)LF 600.00042 512 6025PORT CTB (MOVE)(SGL SLP)(TY 1)LF 330.00043 512 6049PORT CTB (REMOVE)(SGL SLP)(TY 1)LF 600.00044 530 6004DRIVEWAYS (CONC)SY 91.00045 530 6005DRIVEWAYS (ACP)SY 338.00046 530 6006DRIVEWAYS (SURF TREAT)SY 338.00047 533 6003RUMBLE STRIPS (SHOULDER) ASPHALTLF 4,900.00048 540 6001MTL W-BEAM GD FEN (TIM POST)LF 738.00049 542 6001REMOVE METAL BEAM GUARD FENCELF 360.00050 544 6001GUARDRAIL END TREATMENT (INSTALL)EA 3.00051 544 6003GUARDRAIL END TREATMENT (REMOVE)EA 4.00052 545 6003CRASH CUSH ATTEN (MOVE & RESET)EA 2.00053 545 6005CRASH CUSH ATTEN (REMOVE)EA 2.00054 545 6007CRASH CUSH ATTEN (INSTL)(L)(N)(TL3)EA 2.00055 618 6046CONDT (PVC) (SCH 80) (2")LF 277.00056 618 6053CONDT (PVC) (SCH 80) (3")LF 296.00057 618 6054CONDT (PVC) (SCH 80) (3") (BORE)LF 477.00058 618 6058CONDT (PVC) (SCH 80) (4")LF 20.00059 620 6007ELEC CONDR (NO.8) BARELF 1,016.00060 620 6008ELEC CONDR (NO.8) INSULATEDLF 720.00061 620 6009ELEC CONDR (NO.6) BARELF 59.00062 620 6010ELEC CONDR (NO.6) INSULATEDLF 118.00063 624 6010GROUND BOX TY D (162922)W/APRONEA 5.00064 628 6165ELC SRV TY D 120/240 070(NS)AL(E)SP(O)EA 1.00065 644 6001IN SM RD SN SUP&AM TY10BWG(1)SA(P)EA 6.00066 644 6004IN SM RD SN SUP&AM TY10BWG(1)SA(T)EA 2.00067 644 6060IN SM RD SN SUP&AM TYTWT(1)WS(P)EA 1.00068 644 6076REMOVE SM RD SN SUP&AMEA 5.00069 658 6016INSTL DEL ASSM (D-SW)SZ (BRF)GF1 (BI)EA 14.00070 666 6030REFL PAV MRK TY I (W)8"(DOT)(100MIL)LF 124.00071 666 6036REFL PAV MRK TY I (W)8"(SLD)(100MIL)LF 923.00072 666 6048REFL PAV MRK TY I (W)24"(SLD)(100MIL)LF 122.00073 666 6054REFL PAV MRK TY I (W)(ARROW)(100MIL)EA 4.00074 666 6078REFL PAV MRK TY I (W)(WORD)(100MIL)EA 4.00075 666 6342REF PROF PAV MRK TY I(W)4"(SLD)(100MIL)LF 4,941.00076 666 6345REF PROF PAV MRK TY I(Y)4"(SLD)(100MIL)LF 8,302.00077 672 6007REFL PAV MRKR TY I-CEA 55.00078 672 6009REFL PAV MRKR TY II-A-AEA 236.00079 677 6001ELIM EXT PAV MRK & MRKS (4")LF 6,330.00080 677 6003ELIM EXT PAV MRK & MRKS (8")LF 806.00081 677 6008ELIM EXT PAV MRK & MRKS (ARROW)EA 2.00082 677 6012ELIM EXT PAV MRK & MRKS (WORD)EA 2.00083 680 6003INSTALL HWY TRF SIG (SYSTEM)EA 1.00084 682 6001VEH SIG SEC (12")LED(GRN)EA 6.00085 682 6002VEH SIG SEC (12")LED(GRN ARW)EA 1.00086 682 6003VEH SIG SEC (12")LED(YEL)EA 6.00087 682 6004VEH SIG SEC (12")LED(YEL ARW)EA 2.00088 682 6005VEH SIG SEC (12")LED(RED)EA 6.00089 682 6006VEH SIG SEC (12")LED(RED ARW)EA 1.00090 682 6018PED SIG SEC (LED)(COUNTDOWN)EA 2.00091 682 6023BACK PLATE (12")(3 SEC)EA 6.00092 682 6024BACK PLATE (12")(4 SEC)EA 1.00093 684 6028TRF SIG CBL (TY A)(14 AWG)(2 CONDR)LF 167.00094 684 6031TRF SIG CBL (TY A)(14 AWG)(5 CONDR)LF 713.00095 684 6046TRF SIG CBL (TY A)(14 AWG)(20 CONDR)LF 285.00096 686 6029INS TRF SIG PL AM (S)1 ARM(28')EA 1.00097 686 6043INS TRF SIG PL AM(S)1 ARM(40')LUMEA 1.00098 686 6047INS TRF SIG PL AM(S)1 ARM(44')LUMEA 1.00099 687 6001PED POLE ASSEMBLYEA 2.000100 688 6001PED DETECT PUSH BUTTON (APS)EA 2.000101 688 6003PED DETECTOR CONTROLLER UNITEA 2.000102 764 6008STORM SEWER CLEANING (PIPE)(19"-24"DIA)LF 128.000103 764 6017STORM SEWER CLEAN (BOX CULV)(12-<24 SF)LF 78.000104 30766001D-GR HMA TY-B PG64-22TON 858.000105 30766048D-GR HMA TY-D PG76-22TON 429.000106 30766066TACK COATGAL 754.000107 30856001UNDERSEAL COURSEGAL 3,279.000108 60016001PORTABLE CHANGEABLE MESSAGE SIGNDAY 352.000109 60586001BBU SYSTEM (EXTERNAL BATT CABINET)EA 1.000110 61856002TMA (STATIONARY)DAY 30.000111 61856003TMA (MOBILE OPERATION)HR 48.000112 62926001RVDS(PRESENCE DETECTION ONLY)EA 3.000113 62926002RVDS(ADVANCE DETECTION ONLY)EA 2.000114 * INCLUDES FORCE ACCOUNT WORK AMOUNTS AS FOLLOWS: CONTRACTOR FORCE ACCOUNT WORK (PART) $12,000.00