COUNTY: TRAVIS HIGHWAY: SH 71 LENGTH: 4.7140MI CONTROL NUMBER: 0265-02-036, ETCSBE GOAL: 0.0 % PROJECT NUMBER: C 265-2-36, ETC TYPE: INTERCHANGE (NEW OR RECONSTRUCTED) TIME FOR COMPLETION: WORKING DAYS BY CONTRACTOR **GUARANTY: 100,000.00 BIDS RECEIVED UNTIL: 1:00 PM SEPTEMBER 03, 2020 EST.COST: 48,517,239.26 BIDS WILL BE OPENED: 1:00 PM SEPTEMBER 03, 2020 MAIL OR DELIVER BIDS TO: FOR PS&E PROJECT QUESTIONS CALL: TEXAS DEPARTMENT OF TRANSPORTATIONVICTOR VARGAS ATTN: CONSTRUCTION DIVISION - ROOM 1A.2 1001 EAST PARMER LANE STE 200 E RIVERSIDEAUSTIN, TX 78753 AUSTIN TX 78704-1204512/997-2201 FOR QUESTIONS REGARDING A PROPOSAL CALL 512/416-2498 TO REQUEST A PROPOSAL GO TO http://www.dot.state.tx.us/business/pr.htm FOR ELECTRONIC BIDDING VISIT THE WEBSITE BELOW: http://www.txdot.gov/business/letting-bids/ebs.html ------------------------------------------------------------------------------ COUNTY CONTROL LIMITS FROM HIGHWAY PROJECT LIMITS TO ------------------------------------------------------------------------------ TRAVIS0265-02-036AT ROSS ROAD & AT KELLAM ROAD SH 71C 265-2-36. LENGTH: 2.1120 MILES TRAVIS0265-01-119SH 130 SH 71C 265-1-1190.49 MILES EAST OF SH 130 LENGTH: 0.49 MILES TRAVIS0265-02-039AT ROSS ROAD & AT KELLAM ROAD SH 71ROW 265-2-39. LENGTH: 2.1120 MILES ------------------------------------------------------------------------------------------------------------- ITEM DESAPPROXIMATE ALT NO. CD. ITEM DESCRIPTIONUNITQUANTITIESBID PRICEAMOUNTSEQ ------------------------------------------------------------------------------------------------------------- 100 6001PREPARING ROWAC 1.8501 100 6002PREPARING ROWSTA 112.0002 104 6001REMOVING CONC (PAV)SY 2,144.0003 104 6009REMOVING CONC (RIPRAP)SY 3,624.0004 104 6017REMOVING CONC (DRIVEWAYS)SY 2,096.0005 104 6023REMOVING CONC (CTB)LF 5,916.0006 104 6037REMOVE CONC (RAIL)LF 959.0007 104 6044REMOVING CONC (FLUME)SY 153.0008 104 6064REMOVING CONC (MISC)CY 51.0009 105 6037REMOVING STAB BASE AND ASPH PAV(0"-16")SY 81,557.00010 110 6001EXCAVATION (ROADWAY)CY 128,351.30011 110 6002EXCAVATION (CHANNEL)CY 23,803.00012 132 6003EMBANKMENT (FINAL)(ORD COMP)(TY B)CY 44,830.00013 132 6006EMBANKMENT (FINAL)(DENS CONT)(TY C)CY 42,663.00014 132 6047EMBANKMENT (FINAL)(ORD COMP)(TY C1)CY 437,855.10015 160 6003FURNISHING AND PLACING TOPSOIL (4")SY 318,519.00016 162 6002BLOCK SODDINGSY 1,512.00017 164 6001BROADCAST SEED (PERM) (RURAL) (SANDY)SY 318,519.00018 164 6041DRILL SEEDING (TEMP) (WARM)SY 318,519.00019 164 6043DRILL SEEDING (TEMP) (COOL)SY 318,519.00020 168 6001VEGETATIVE WATERINGMG 7,903.00021 169 6001SOIL RETENTION BLANKETS (CL 1) (TY A)SY 318,519.00022 247 6366FL BS (CMP IN PLC)(TY A GR 5)(FNAL POS)CY 1,610.00023 247 6382FL BS (CMP IN PLC)(TY A GR 5)(8")SY 58,332.00024 260 6043LIME (HYD, COM OR QK)(SLURRY)TON 1,033.30025 260 6073LIME TRT (SUBGRADE)(8")SY 55,554.00026 260 6079LIME TRT (SUBGRADE)(6")SY 2,466.00027 275 6001CEMENTTON 869.00028 275 6003CEMENT TREAT (NEW BASE) (6")SY 89,128.00029 310 6001PRIME COAT (MULTI OPTION)GAL 30,102.00030 340 6011D-GR HMA(SQ) TY-B PG64-22TON 322.00031 347 6001TOM (ASPHALT) PG 76-22TON 258.00032 347 6002TOM-C (AGGREGATE) SAC-ATON 264.00033 347 6006TOM - C (AGGREGATE) SAC - BTON 3,332.00034 347 6008TACK COATGAL 16,279.00035 354 6003PLAN & TEXT ASPH CONC PAV(0" TO 3")SY 11,381.00036 360 6005CONC PVMT (CONT REINF - CRCP) (11")SY 82,051.00037 400 6001STRUCT EXCAVCY 20,414.00038 400 6005CEM STABIL BKFLCY 26,649.00039 400 6008CUT & RESTORE ASPH PAVINGSY 140.00040 402 6001TRENCH EXCAVATION PROTECTIONLF 14,837.00041 403 6001TEMPORARY SPL SHORINGSF 6,025.00042 416 6002DRILL SHAFT (24 IN)LF 60.00043 416 6003DRILL SHAFT (30 IN)LF 3,200.00044 416 6004DRILL SHAFT (36 IN)LF 7,580.00045 416 6015DRILL SHAFT (NON - REINFORCED) (12 IN)LF 6.00046 416 6018DRILL SHAFT (SIGN MTS) (24 IN)LF 53.00047 416 6029DRILL SHAFT (RDWY ILL POLE) (30 IN)LF 130.00048 416 6031DRILL SHAFT (TRF SIG POLE) (30 IN)LF 22.00049 416 6032DRILL SHAFT (TRF SIG POLE) (36 IN)LF 39.00050 416 6034DRILL SHAFT (TRF SIG POLE) (48 IN)LF 154.00051 420 6013CL C CONC (ABUT)CY 249.60052 420 6019CL C CONC (ABUT)(EXTEND)CY 18.60053 420 6029CL C CONC (CAP)CY 237.50054 420 6037CL C CONC (COLUMN)CY 319.40055 420 6043CL C CONC (FOOTING)CY 839.70056 420 6068CL C CONC (SIGN COLUMN)CY 249.50057 420 6074CL C CONC (MISC)CY 53.70058 420 6134CL C CONC (SIGN FOOTING)CY 76.80059 420 6166CL C CONC (TIE BEAM)CY 380.70060 422 6001REINF CONC SLABSF 46,800.00061 422 6003REINF CONC SLAB (EXTEND SLAB)SF 11,137.00062 422 6015APPROACH SLABCY 307.00063 423 6001RETAINING WALL (MSE)SF 158,546.00064 425 6036PRESTR CONC GIRDER (TX34)LF 1,482.00065 425 6039PRESTR CONC GIRDER (TX54)LF 5,820.20066 429 6007CONC STR REPAIR (VERTICAL & OVERHEAD)SF 61.60067 432 6001RIPRAP (CONC)(4 IN)CY 438.00068 432 6002RIPRAP (CONC)(5 IN)CY 897.00069 432 6003RIPRAP (CONC)(6 IN)CY 29.00070 432 6029RIPRAP (STONE COMMON)(GROUT)(8 IN)CY 1,180.00071 432 6033RIPRAP (STONE PROTECTION)(18 IN)CY 7,306.00072 432 6036RIPRAP (STONE PROTECTION)(30 IN)CY 1,550.00073 432 6045RIPRAP (MOW STRIP)(4 IN)CY 521.00074 438 6008CLEANING AND SEALING JOINTS (CL 7)LF 104.00075 442 6008STR STEEL (MISCELLANEOUS BRIDGE)LB 28,053.00076 450 6016RAIL (TY T552)LF 770.00077 450 6023RAIL (TY SSTR)LF 10,774.60078 450 6048RAIL (HANDRAIL)(TY B)LF 1,774.00079 454 6001SEALED EXPANSION JOINT (4 IN) (SEJ - A)LF 440.00080 454 6004ARMOR JOINT (SEALED)LF 30.00081 462 6005CONC BOX CULV (4 FT X 4 FT)LF 51.00082 462 6010CONC BOX CULV (6 FT X 3 FT)LF 336.00083 462 6011CONC BOX CULV (6 FT X 4 FT)LF 1,095.00084 462 6014CONC BOX CULV (7 FT X 3 FT)LF 976.00085 462 6019CONC BOX CULV (8 FT X 4 FT)LF 764.00086 462 6020CONC BOX CULV (8 FT X 5 FT)LF 73.00087 462 6029CONC BOX CULV (10 FT X 5 FT)LF 66.00088 464 6003RC PIPE (CL III)(18 IN)LF 622.00089 464 6005RC PIPE (CL III)(24 IN)LF 19,538.00090 464 6007RC PIPE (CL III)(30 IN)LF 3,387.00091 464 6008RC PIPE (CL III)(36 IN)LF 923.00092 464 6009RC PIPE (CL III)(42 IN)LF 64.00093 464 6017RC PIPE (CL IV)(18 IN)LF 482.00094 464 6025RC PIPE (CL V)(18 IN)LF 782.00095 465 6002MANH (COMPL)(PRM)(48IN)EA 16.00096 465 6003MANH (COMPL)(PRM)(60IN)EA 52.00097 465 6021INLET (COMPL)(PCO)(5FT)(NONE)EA 36.00098 465 6022INLET (COMPL)(PCO)(5FT)(LEFT)EA 20.00099 465 6023INLET (COMPL)(PCO)(5FT)(RIGHT)EA 26.000100 465 6133INLET (COMPL)(PSL)(FG)(4FTX5FT-3FTX5FT)EA 30.000101 465 6136INLET (COMPL)(PSL)(FG)(5FTX5FT-3FTX5FT)EA 12.000102 465 6154INLET (COMPL)(PAZD)(RC)(5FTX5FT)EA 16.000103 465 6158INLET(COMPL)(PAZD)(FG)(3FTX3FT-3FTX3FT)EA 2.000104 465 6225JCT BOX (COMPL)(SPL)EA 2.000105 465 6235INLET (COMPL)(RWI)(TY I)EA 49.000106 465 6257INLET(COMPL)(WALL)(SPL)EA 21.000107 466 6132HEADWALL (CH - PW - S) (DIA= 30 IN)EA 1.000108 466 6167WINGWALL (FW - S) (HW=6 FT)EA 1.000109 466 6181WINGWALL (PW - 1) (HW=6 FT)EA 6.000110 467 6005SET (TY I) (24 IN) (3: 1) (C)EA 16.000111 467 6008SET (TY I) (30 IN) (3: 1) (C)EA 3.000112 467 6054SET (TY I)(S=10 FT)(HW=5FT)(6:1)(P)EA 2.000113 467 6147SET (TY I)(S= 4 FT)(HW= 4 FT)(6:1) (P)EA 2.000114 467 6257SET (TY I)(S= 7 FT)(HW= 7 FT)(4:1) (C)EA 1.000115 467 6278SET (TY I)(S= 8 FT)(HW= 5 FT)(6:1) (P)EA 2.000116 467 6423SET (TY II) (30 IN) (RCP) (6: 1) (P)EA 2.000117 467 6454SET (TY II) (36 IN) (RCP) (6: 1) (P)EA 2.000118 467 6460SET (TY II) (42 IN) (CMP) (6: 1) (P)EA 4.000119 496 6002REMOV STR (INLET)EA 5.000120 496 6003REMOV STR (MANHOLE)EA 5.000121 496 6007REMOV STR (PIPE)LF 3,290.000122 496 6008REMOV STR (BOX CULVERT)LF 850.000123 496 6013REMOV STR (BRIDGE SLAB)EA 1.000124 496 6017REMOV STR (ABUTMENT)EA 2.000125 496 6043REMOV STR (SMALL FENCE)LF 11,779.000126 500 6001MOBILIZATIONLS 1.000127 502 6001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO 35.000128 506 6002ROCK FILTER DAMS (INSTALL) (TY 2)LF 120.000129 506 6011ROCK FILTER DAMS (REMOVE)LF 120.000130 506 6020CONSTRUCTION EXITS (INSTALL) (TY 1)SY 280.000131 506 6024CONSTRUCTION EXITS (REMOVE)SY 280.000132 506 6038TEMP SEDMT CONT FENCE (INSTALL)LF 26,377.000133 506 6039TEMP SEDMT CONT FENCE (REMOVE)LF 26,377.000134 506 6040BIODEG EROSN CONT LOGS (INSTL) (8")LF 4,051.000135 506 6043BIODEG EROSN CONT LOGS (REMOVE)LF 4,051.000136 508 6001CONSTRUCTING DETOURSSY 12,128.000137 512 6005PORT CTB (FUR & INST)(F-SHAPE)(TY 1)LF 6,810.000138 512 6009PORT CTB (FUR & INST)(LOW PROF)(TY 1)LF 560.000139 512 6010PORT CTB (FUR & INST)(LOW PROF)(TY 2)LF 160.000140 512 6029PORT CTB (MOVE)(F-SHAPE)(TY 1)LF 12,630.000141 512 6033PORT CTB (MOVE)(LOW PROF)(TY 1)LF 960.000142 512 6034PORT CTB (MOVE)(LOW PROF)(TY 2)LF 160.000143 512 6053PORT CTB (REMOVE)(F-SHAPE)(TY 1)LF 6,810.000144 512 6057PORT CTB (REMOVE)(LOW PROF)(TY 1)LF 560.000145 512 6058PORT CTB (REMOVE)(LOW PROF)(TY 2)LF 160.000146 529 6008CONC CURB & GUTTER (TY II)LF 25,692.000147 530 6004DRIVEWAYS (CONC)SY 8,322.000148 531 6003CONC SIDEWALKS (6")SY 11,694.000149 540 6001MTL W-BEAM GD FEN (TIM POST)LF 6,126.000150 540 6006MTL BEAM GD FEN TRANS (THRIE-BEAM)EA 21.000151 540 6016DOWNSTREAM ANCHOR TERMINAL SECTIONEA 15.000152 542 6001REMOVE METAL BEAM GUARD FENCELF 113.000153 544 6001GUARDRAIL END TREATMENT (INSTALL)EA 20.000154 545 6003CRASH CUSH ATTEN (MOVE & RESET)EA 8.000155 545 6005CRASH CUSH ATTEN (REMOVE)EA 5.000156 545 6019CRASH CUSH ATTEN (INSTL)(S)(N)(TL3)EA 5.000157 556 6006PIPE UNDERDRAINS (TY 6) (6")LF 8,518.000158 610 6104IN RD IL (U/P) (TY 1) (150W EQ) LEDEA 16.000159 610 6198IN RD IL (TY SA) 40B-8 (250W EQ) LEDEA 1.000160 610 6214IN RD IL (TY SA) 40T-8 (250W EQ) LEDEA 13.000161 618 6023CONDT (PVC) (SCH 40) (2")LF 215.000162 618 6046CONDT (PVC) (SCH 80) (2")LF 5,156.000163 618 6047CONDT (PVC) (SCH 80) (2") (BORE)LF 750.000164 618 6053CONDT (PVC) (SCH 80) (3")LF 760.000165 618 6054CONDT (PVC) (SCH 80) (3") (BORE)LF 3,260.000166 618 6058CONDT (PVC) (SCH 80) (4")LF 1,170.000167 618 6062CONDT (RM) (3/4")LF 472.000168 618 6070CONDT (RM) (2")LF 130.000169 620 6003ELEC CONDR (NO.12) BARELF 476.000170 620 6004ELEC CONDR (NO.12) INSULATEDLF 952.000171 620 6007ELEC CONDR (NO.8) BARELF 10,050.000172 620 6008ELEC CONDR (NO.8) INSULATEDLF 9,410.000173 620 6009ELEC CONDR (NO.6) BARELF 770.000174 620 6010ELEC CONDR (NO.6) INSULATEDLF 1,540.000175 620 6011ELEC CONDR (NO.4) BARELF 405.000176 620 6012ELEC CONDR (NO.4) INSULATEDLF 1,215.000177 621 6005TRAY CABLE (4 CONDR) (12 AWG)LF 8,940.000178 624 6001GROUND BOX TY A (122311)EA 6.000179 624 6002GROUND BOX TY A (122311)W/APRONEA 15.000180 624 6010GROUND BOX TY D (162922)W/APRONEA 28.000181 628 6002REMOVE ELECTRICAL SERVICESEA 2.000182 628 6041ELC SRV TY A 240/480 060(NS)SS(E)GC(O)EA 4.000183 628 6165ELC SRV TY D 120/240 070(NS)AL(E)SP(O)EA 2.000184 628 6267ELC SRV TY D 120/240 125(NS)SS(N)TP(O)EA 1.000185 636 6001ALUMINUM SIGNS (TY A)SF 1,164.000186 636 6002ALUMINUM SIGNS (TY G)SF 777.000187 636 6003ALUMINUM SIGNS (TY O)SF 763.000188 644 6001IN SM RD SN SUP&AM TY10BWG(1)SA(P)EA 1.000189 644 6002IN SM RD SN SUP&AM TY10BWG(1)SA(P-BM)EA 2.000190 644 6004IN SM RD SN SUP&AM TY10BWG(1)SA(T)EA 26.000191 644 6007IN SM RD SN SUP&AM TY10BWG(1)SA(U)EA 4.000192 644 6027IN SM RD SN SUP&AM TYS80(1)SA(P)EA 5.000193 644 6030IN SM RD SN SUP&AM TYS80(1)SA(T)EA 35.000194 644 6033IN SM RD SN SUP&AM TYS80(1)SA(U)EA 11.000195 644 6064IN BRIDGE MNT CLEARANCE SGN ASSM(TY N)EA 8.000196 644 6084IN SRSS & AM (RAIL)(90 MPH)(T MOUNT)EA 1.000197 647 6001INSTALL LRSS (STRUCT STEEL)LB 2,599.000198 650 6032INS OH SN SUP(30 FT CANT)EA 4.000199 650 6089INS OH SN SUP(80 FT BRDG)EA 3.000200 650 6204REMOVE OVERHD SIGN SUPEA 1.000201 662 6001WK ZN PAV MRK NON-REMOV (W)4"(BRK)LF 19,512.000202 662 6004WK ZN PAV MRK NON-REMOV (W)4"(SLD)LF 24,079.000203 662 6034WK ZN PAV MRK NON-REMOV (Y)4"(SLD)LF 24,395.000204 666 6035REFL PAV MRK TY I (W)8"(SLD)(090MIL)LF 10,788.000205 666 6041REFL PAV MRK TY I (W)12"(SLD)(090MIL)LF 1,372.000206 666 6047REFL PAV MRK TY I (W)24"(SLD)(090MIL)LF 469.000207 666 6053REFL PAV MRK TY I (W)(ARROW)(090MIL)EA 16.000208 666 6056REFL PAV MRK TY I(W)(DBL ARROW)(090MIL)EA 8.000209 666 6062REFL PAV MRK TY I(W)(UTURN ARW)(090MIL)EA 8.000210 666 6077REFL PAV MRK TY I (W)(WORD)(090MIL)EA 24.000211 666 6101REF PAV MRK TY I(W)36"(YLD TRI)(090MIL)EA 44.000212 666 6299RE PM W/RET REQ TY I (W)4"(BRK)(090MIL)LF 10,178.000213 666 6302RE PM W/RET REQ TY I (W)4"(SLD)(090MIL)LF 25,150.000214 666 6314RE PM W/RET REQ TY I (Y)4"(SLD)(090MIL)LF 28,248.000215 672 6007REFL PAV MRKR TY I-CEA 195.000216 672 6009REFL PAV MRKR TY II-A-AEA 107.000217 672 6010REFL PAV MRKR TY II-C-REA 463.000218 677 6001ELIM EXT PAV MRK & MRKS (4")LF 20,670.000219 680 6003INSTALL HWY TRF SIG (SYSTEM)EA 2.000220 680 6004REMOVING TRAFFIC SIGNALSEA 4.000221 681 6001TEMP TRAF SIGNALSEA 2.000222 682 6001VEH SIG SEC (12")LED(GRN)EA 36.000223 682 6002VEH SIG SEC (12")LED(GRN ARW)EA 4.000224 682 6003VEH SIG SEC (12")LED(YEL)EA 36.000225 682 6004VEH SIG SEC (12")LED(YEL ARW)EA 8.000226 682 6005VEH SIG SEC (12")LED(RED)EA 36.000227 682 6006VEH SIG SEC (12")LED(RED ARW)EA 4.000228 682 6017PED SIG SEC (LED)(2 INDICATIONS)EA 24.000229 682 6018PED SIG SEC (LED)(COUNTDOWN)EA 24.000230 682 6023BACK PLATE (12")(3 SEC)EA 36.000231 682 6024BACK PLATE (12")(4 SEC)EA 4.000232 684 6007TRF SIG CBL (TY A)(12 AWG)(2 CONDR)LF 6,500.000233 684 6009TRF SIG CBL (TY A)(12 AWG)(4 CONDR)LF 6,625.000234 684 6010TRF SIG CBL (TY A)(12 AWG)(5 CONDR)LF 11,218.000235 684 6012TRF SIG CBL (TY A)(12 AWG)(7 CONDR)LF 1,292.000236 685 6006REMOV RDSD FLSH BCN AM (SOLAR PWRD)EA 1.000237 686 6035INS TRF SIG PL AM(S)1 ARM(32')LUMEA 2.000238 686 6039INS TRF SIG PL AM(S)1 ARM(36')LUMEA 2.000239 686 6043INS TRF SIG PL AM(S)1 ARM(40')LUMEA 1.000240 686 6055INS TRF SIG PL AM(S)1 ARM(50')LUMEA 1.000241 686 6059INS TRF SIG PL AM(S)1 ARM(55')LUMEA 3.000242 686 6063INS TRF SIG PL AM(S)1 ARM(60')LUMEA 3.000243 687 6001PED POLE ASSEMBLYEA 10.000244 688 6001PED DETECT PUSH BUTTON (APS)EA 24.000245 688 6003PED DETECTOR CONTROLLER UNITEA 2.000246 730 6107FULL - WIDTH MOWINGCYC 5.000247 734 6002LITTER REMOVALCYC 5.000248 740 6002GRAFFITI REMOVAL (PAINTING)SF 200.000249 752 6003TREE TRIMMING / BRUSH REMOVALMI 1.000250 752 6005TREE REMOVAL (4" - 12" DIA)EA 32.000251 752 6006TREE REMOVAL (12" - 18" DIA)EA 1.000252 752 6007TREE REMOVAL (18" - 24" DIA)EA 1.000253 772 6001POST AND CABLE FENCE (REMOVAL)LF 6,381.000254 780 6004CONC CRCK REPR(DISCRETE)(ROUT AND SEAL)LF 193.000255 784 6003REP STL BRIDGE MEMBER (DIAPHRAGM)EA 3.000256 784 6034REP STL BRIDGE MEMBER(STRAIGHTEN MEMB)EA 1.000257 785 6011BRIDGE JOINT REPLACEMENT (SEJ)LF 416.000258 30766001D-GR HMA TY-B PG64-22TON 28,009.000259 30766038D-GR HMA TY-D PG64-22 (LEVEL-UP)TON 5,267.000260 30766048D-GR HMA TY-D PG76-22TON 6,453.000261 30766066TACK COATGAL 51,098.000262 40146004INTRLCK ART CONC BLKS W/CABLE (6" MIN)SF 13,646.000263 40276001TEMP CONSTRUCTION ACCESSLS 1.000264 60016002PORTABLE CHANGEABLE MESSAGE SIGNEA 4.000265 60586001BBU SYSTEM (EXTERNAL BATT CABINET)EA 2.000266 60626006ITS RADIO (SNGL)(900 MHZ)-C-UEA 2.000267 61516001REMOVE AND RELOCATE DMS SYSTEMEA 1.000268 61856002TMA (STATIONARY)DAY 3,472.000269 61856005TMA (MOBILE OPERATION)DAY 744.000270 62926001RVDS(PRESENCE DETECTION ONLY)EA 12.000271 62926002RVDS(ADVANCE DETECTION ONLY)EA 4.000272 72076014FIRE HYDRANTEA 8.000273 72076016JACK BORE ASTM A134 STEEL MIN THICK 3/8LF 135.000274 72076018PIPE, 6" DIA. DI CLASS 350 (ALL DEPTHS)LF 80.000275 72076025AUTO COMBO AIR AND VAC RELEASE VALVE 2"EA 2.000276 72076034DUCTILE IRON FITTINGSTON 5.420277 72076035VALVE(GATE)(6")EA 10.000278 72076045CONNECT TO EXIST(16")(WL CUT&PLUG)EA 4.000279 72076059PIPE(D.I.)(16")(CL 250)LF 80.000280 72076066WET CONNECTIONS, 16" DIA. X 16" DIA.EA 2.000281 72076068DRAIN VALVE ASSEMBLIESEA 2.000282 72076069VALVE, GATE VALVE, 24" DIAEA 5.000283 72076070REMOVE EXISTING FIRE HYDRANTEA 7.000284 72076071VALVE, GATE VALVE, 16" DIAEA 2.000285 72076072PIPE(24")(ALL DEPTHS)(INCL EXCAV/BFILL)LF 4,105.000286 72076073STEEL ENCASE PIPE(36")W/SPACER,OPEN CUTLF 185.000287 72076074ABANDON 24" PIPE IN PLACE(GROUTING)LF 3,800.000288 72076075ABANDON 16" PIPE IN PLACE(GROUTING)LF 150.000289 72076076ABANDON & REMOVE EXISTING 24" PIPELF 890.000290 ROAD USER COST 800 6002NO. OF DAYS MILESTONE 1$/D 5,750.000291 ** THE NO. OF DAYS MILESTONE 1 OF 194.000 WILL BE USED ONLY FOR BID COMPARISON AND AS A DEDUCTION OR AS A CREDIT IN ACCORDANCE WITH ITEM 8. THE ESTIMATED COST OF THIS CONTRACT DOES NOT INCLUDE THIS COST.