COUNTY: WICHITA HIGHWAY: SH 240 LENGTH: 0MI CONTROL NUMBER: 0156-02-033, ETCDBE GOAL: 6.0 % PROJECT NUMBER: F 2021(707) TYPE: SAFETY IMPROVEMENT PROJECTS TIME FOR COMPLETION: 152 WORKING DAYSGUARANTY: 37,000.00 BIDS RECEIVED UNTIL: 1:00 PM JULY 01, 2021 EST.COST: 1,864,095.20 BIDS WILL BE OPENED: 1:00 PM JULY 01, 2021 MAIL OR DELIVER BIDS TO: FOR PS&E PROJECT QUESTIONS CALL: TEXAS DEPARTMENT OF TRANSPORTATIONCALLAN COLTHARP ATTN: CONSTRUCTION DIVISION - ROOM 1A.2 2844 EAST CENTRAL FREEWAY 200 E RIVERSIDEWICHITA FALLS, TX 76301 AUSTIN TX 78704-1204940/397-2074 FOR QUESTIONS REGARDING A PROPOSAL CALL 512/416-2498 TO REQUEST A PROPOSAL GO TO http://www.dot.state.tx.us/business/pr.htm FOR ELECTRONIC BIDDING VISIT THE WEBSITE BELOW: http://www.txdot.gov/business/letting-bids/ebs.html ------------------------------------------------------------------------------ COUNTY CONTROL LIMITS FROM HIGHWAY PROJECT LIMITS TO ------------------------------------------------------------------------------ WICHITA0156-02-033IH 44 SH 240F 2021(707)NEAR ROBINSON ROAD LENGTH: MILES WICHITA0156-03-049NEAR ROBINSON ROAD SH 240F 2021(707)2ND STREET LENGTH: MILES ------------------------------------------------------------------------------------------------------------- ITEM DESAPPROXIMATE ALT NO. CD. ITEM DESCRIPTIONUNITQUANTITIESBID PRICEAMOUNTSEQ ------------------------------------------------------------------------------------------------------------- 100 6002PREPARING ROWSTA 6.0001 104 6009REMOVING CONC (RIPRAP)SY 440.0002 104 6014REMOVING CONC (FOUNDATIONS)CY 4.0003 104 6028REMOVING CONC (MISC)SY 24.0004 110 6002EXCAVATION (CHANNEL)CY 12.0005 132 6003EMBANKMENT (FINAL)(ORD COMP)(TY B)CY 432.0006 162 6002BLOCK SODDINGSY 2,435.0007 168 6001VEGETATIVE WATERINGMG 8.8008 400 6005CEM STABIL BKFLCY 33.0009 400 6006CUT & RESTORING PAVSY 22.00010 402 6001TRENCH EXCAVATION PROTECTIONLF 100.00011 403 6001TEMPORARY SPL SHORINGSF 72.00012 416 6032DRILL SHAFT (TRF SIG POLE) (36 IN)LF 14.00013 416 6034DRILL SHAFT (TRF SIG POLE) (48 IN)LF 66.00014 420 6009CL A CONC (COLLAR)EA 5.00015 432 6002RIPRAP (CONC)(5 IN)CY 30.90016 432 6006RIPRAP (CONC)(CL B)CY 2.10017 432 6031RIPRAP (STONE PROTECTION)(12 IN)CY 120.00018 432 6045RIPRAP (MOW STRIP)(4 IN)CY 303.00019 451 6019RETROFIT RAIL (TY T631)LF 425.00020 462 6010CONC BOX CULV (6 FT X 3 FT)LF 8.00021 462 6045CONC BOX CULV (3 FT X 2 FT)(EXTEND)LF 29.00022 462 6046CONC BOX CULV (3 FT X 3 FT)(EXTEND)LF 12.00023 462 6047CONC BOX CULV (4 FT X 2 FT)(EXTEND)LF 22.00024 462 6049CONC BOX CULV (4 FT X 4 FT)(EXTEND)LF 18.50025 462 6051CONC BOX CULV (5 FT X 3 FT)(EXTEND)LF 5.00026 462 6053CONC BOX CULV (5 FT X 5 FT)(EXTEND)LF 11.00027 462 6063CONC BOX CULV (8 FT X 4 FT)(EXTEND)LF 12.00028 462 6073CONC BOX CULV (10 FT X 5 FT)(EXTEND)LF 12.00029 462 6110CONC BOX CULVERT (2 FT X 2 FT) (EXTEND)LF 12.00030 464 6003RC PIPE (CL III)(18 IN)LF 30.00031 464 6005RC PIPE (CL III)(24 IN)LF 332.00032 466 6005HEADWALL (CH - FW - 0) (DIA= 24 IN)EA 1.00033 466 6097HEADWALL (CH - PW - 0) (DIA= 24 IN)EA 1.00034 466 6150WINGWALL (FW - 0) (HW=3 FT)EA 11.00035 466 6151WINGWALL (FW - 0) (HW=4 FT)EA 3.00036 466 6152WINGWALL (FW - 0) (HW=5 FT)EA 2.00037 466 6153WINGWALL (FW - 0) (HW=6 FT)EA 4.00038 467 6202SET (TY I)(S= 6 FT)(HW= 2 FT)(6:1) (P)EA 1.00039 467 6319SET (TY II) (12 IN) (CMP) (6: 1) (P)EA 8.00040 467 6348SET (TY II) (18 IN) (CMP) (6: 1) (P)EA 8.00041 467 6363SET (TY II) (18 IN) (RCP) (6: 1) (P)EA 40.00042 467 6380SET (TY II) (24 IN) (CMP) (6: 1) (P)EA 6.00043 467 6395SET (TY II) (24 IN) (RCP) (6: 1) (P)EA 4.00044 467 6423SET (TY II) (30 IN) (RCP) (6: 1) (P)EA 8.00045 467 6429SET (TY II) (32 IN) (RCP) (6: 1) (P)EA 2.00046 467 6454SET (TY II) (36 IN) (RCP) (6: 1) (P)EA 4.00047 480 6001CLEAN EXIST CULVERTSEA 1.00048 496 6005REMOV STR (WINGWALL)EA 21.00049 496 6006REMOV STR (HEADWALL)EA 2.00050 496 6007REMOV STR (PIPE)LF 118.00051 500 6001MOBILIZATIONLS 1.00052 502 6001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO 9.00053 506 6002ROCK FILTER DAMS (INSTALL) (TY 2)LF 312.00054 506 6011ROCK FILTER DAMS (REMOVE)LF 312.00055 506 6038TEMP SEDMT CONT FENCE (INSTALL)LF 2,960.00056 506 6039TEMP SEDMT CONT FENCE (REMOVE)LF 2,960.00057 506 6041BIODEG EROSN CONT LOGS (INSTL) (12")LF 2,960.00058 506 6043BIODEG EROSN CONT LOGS (REMOVE)LF 2,960.00059 530 6016 DRIVEWAYS (BASE)SY 51.00060 533 6003RUMBLE STRIPS (SHOULDER) ASPHALTLF 66,158.00061 533 6004RUMBLE STRIPS (CENTERLINE) ASPHALTLF 30,080.00062 540 6001MTL W-BEAM GD FEN (TIM POST)LF 3,825.00063 540 6006MTL BEAM GD FEN TRANS (THRIE-BEAM)EA 1.00064 540 6016DOWNSTREAM ANCHOR TERMINAL SECTIONEA 2.00065 540 6017MTL BM GD FEN (LONG SPAN SYSTEM)LF 25.00066 540 6020MTL W - BEAM GD FEN (LOW FILL CULVERT)LF 300.00067 542 6001REMOVE METAL BEAM GUARD FENCELF 2,475.00068 542 6002REMOVE TERMINAL ANCHOR SECTIONEA 7.00069 542 6003REMOVE DOWNSTREAM ANCHOR TERMINALEA 2.00070 544 6001GUARDRAIL END TREATMENT (INSTALL)EA 31.00071 544 6003GUARDRAIL END TREATMENT (REMOVE)EA 16.00072 618 6023CONDT (PVC) (SCH 40) (2")LF 10.00073 618 6029CONDT (PVC) (SCH 40) (3")LF 105.00074 618 6054CONDT (PVC) (SCH 80) (3") (BORE)LF 397.00075 620 6004ELEC CONDR (NO.12) INSULATEDLF 160.00076 620 6009ELEC CONDR (NO.6) BARELF 510.00077 620 6010ELEC CONDR (NO.6) INSULATEDLF 1,044.00078 624 6002GROUND BOX TY A (122311)W/APRONEA 5.00079 624 6008GROUND BOX TY C (162911)W/APRONEA 1.00080 628 6009ELC SRV TY A 120/240 060(NS)SS(E)SP(O)EA 1.00081 636 6001ALUMINUM SIGNS (TY A)SF 32.00082 644 6027IN SM RD SN SUP&AM TYS80(1)SA(P)EA 2.00083 658 6062INSTL DEL ASSM (D-SW)SZ 1(BRF)GF2(BI)EA 76.00084 658 6109INSTL OM ASSM (OM-2Z)(WFLX)SRF(BI)EA 25.00085 666 6147REFL PAV MRK TY I (Y)24"(SLD)(100MIL)LF 24.00086 666 6300RE PM W/RET REQ TY I (W)4"(BRK)(100MIL)LF 1,200.00087 666 6303RE PM W/RET REQ TY I (W)4"(SLD)(100MIL)LF 120,368.00088 666 6312RE PM W/RET REQ TY I (Y)4"(BRK)(100MIL)LF 7,563.00089 666 6315RE PM W/RET REQ TY I (Y)4"(SLD)(100MIL)LF 82,917.00090 668 6076PREFAB PAV MRK TY C (W) (24") (SLD)LF 500.00091 672 6009REFL PAV MRKR TY II-A-AEA 1,420.00092 672 6010REFL PAV MRKR TY II-C-REA 320.00093 680 6002INSTALL HWY TRF SIG (ISOLATED)EA 1.00094 680 6004REMOVING TRAFFIC SIGNALSEA 1.00095 682 6005VEH SIG SEC (12")LED(RED)EA 16.00096 682 6022BACK PLATE (12")(2 SEC)EA 16.00097 684 6029TRF SIG CBL (TY A)(14 AWG)(3 CONDR)LF 510.00098 685 6004INSTL RDSD FLSH BCN ASSM (SOLAR PWRD)EA 2.00099 686 6039INS TRF SIG PL AM(S)1 ARM(36')LUMEA 1.000100 686 6053INS TRF SIG PL AM(S)1 ARM(50')EA 2.000101 686 6055INS TRF SIG PL AM(S)1 ARM(50')LUMEA 1.000102 61856002TMA (STATIONARY)DAY 177.000103 61856005TMA (MOBILE OPERATION)DAY 10.000104