2004 English Special Provisions for Pharr - District 21 (Statewide & Districtwide, Current)


SP672-004  PDF  RTF  Raised Pavement Markers - Measurement will be paid for at the unit price bid for Jiggle Bar Tile Reflectorized Pavement Marker Traffic Button or Plowable Reflectorized Pavement Marker Districtwide Use.
SP666-008  PDF  RTF  Reflectorized Pavement Markings - Acrylic or epoxy sealer, or Type II markings when used as a sealer for Type I markings, will be measured by the foot; by each word, symbol or shape by any other unit shown on the plans. Districtwide Use.
SP400-007  PDF  RTF  Excavation and Backfill for Structures - Unless otherwise shown on the plans, the sand backfill shall have 70-100% passing a No. 10 sieve. The plastic Index (PI) as determined by Test Method Tex-106-E shall not exceed 6. Districtwide Use.
SP400-001  PDF  RTF  Excavation and Backfill for Structures - Allow for payment of gravel bedding material and sand backfll, and to specifiy sand's and gravel's gradation requirements. Districtwide Use.
SP302-013  PDF  RTF  Aggregates for Surface Treatments - Modifies Article 302.2 Materials, Section A. Aggregate, Table 2. Districtwide Use.
SP302-003  PDF  RTF  Aggregates for Surface Treatments - Aggregate gradation requirements for grade 4 aggregate. Districtwide Use.
SP300-031  PDF  RTF  Asphalts, Oils, and Emulsions - This creates a description code for a speciality prime coat binder for EC-30. Districtwide Use.
SP247-041  PDF  RTF  Flexible Base - Adds ride quality with only one lift of Hot Mix ACP or a 1 or 2 course surface treatment for the final surface for quality control and provides recycled materials that have a maximum sulfate content of 3000 ppm when tested in accordance with Tex-145-E. SP 247---041 contains the requirements of 247---033 and 247---026 and may be used in lieu of 247---033. Districtwide Use.
SP247-026  PDF  RTF  Flexible Base - Adds ride quality with only one lift of Hot Mix ACP or a 1 or 2 course surface treatment for the final surface for quality control and provides recycled materials that have a maximum sulfate content of 3000 ppm when tested in accordance with Tex-145-E. SP 247---026 contains the requirements of 247---020 and 247---016 and may be used in lieu of 247---020. Replaces SP247-016 . Districtwide Use.
SP164-006  PDF  RTF  Seeding for Erosion Control - Adds native grass species that are well adapted for arid South Texas. Includes the requirements of required SP 164---002. Districtwide Use.

2004 English Special Provisions By District (Statewide & Districtwide, Current)
2004 English Special Provisions by Item (Statewide & Districtwide, Current)
Specification Information