Terminology and Notation. LRFD refers to Load and Resistance Factor
Design, a design methodology that makes use of load factors and resistance
factors based on the known variability of applied loads and material properties.
Bracketed <references> reference relevant sections of the AASHTO LRFD Bridge
Design Specifications.
Limit states. TxDOT recommends the following limit states for design of bridge system components
<Article 3.4.1>:
| Component |
Limit State |
| Prestressed concrete beams |
Strength I and IV and Service I and III. Fatigue and extreme limit states need not be checked. Live load deflection need not be checked. |
Load Factors. TxDOT recommends the
following permanent loads <Article 3.5>: The
engineer may reduce the maximum load factor
for wearing surfaces and utilities <DW in
Table 3.4.1-2> to 1.25.
General
Design all bridge components for 2 in. of future asphaltic concrete overlay at
0.140 kips per cu. ft.
Corrosion Protection Measures In order to gain
increased corrosion protection for projects located above the "Ice
Line" and in
lieu of specific direction from a District or Area office, do the following:
- For slabs on stringers, use 8.5 in. thick deck slabs with 2.5 in. top
cover {Bridge standard drawings will have to be modified when used for
projects above the ice line.}
- Use Class "S" (HPC) in the bridge deck
- Use epoxy-coated reinforcing for both mats of steel in the bridge deck.
- Use Class "C" (HPC) for all bent caps, columns and abutments regardless
of their locations relative to bridge expansion joints.
- Use HPC in beams and all superstructure elements in the Lubbock and
Amarillo Districts only.
- Use HPC and epoxy coated reinforcing in all concrete bridge railing members.
- Limit the use of open bridge rails that will allow deicing chemicals to
run down the face of the outside beam.
- Do not use any of the Concrete Surface Treatments as provided under Item
428 of the Texas Standard Specifications. Concrete Surface Treatments are
largely ineffective when used in conjunction with HPC.
- Slope caps forward and back between bearing seats so that water will not
pond on top of the caps.
We do not recommend/require any of the following:
- Epoxy waterproofing of bent caps, abutment caps, abutment backwalls, or
columns. The exception is in LBB where epoxy waterproofing is to be used at
all caps under expansion joints.
- HPC in piling, drilled shafts or footings.
- Epoxy coated reinforcing bars for substructure elements (i.e. bent caps,
abutments, columns, piling, drilled shafts or footings.)
- Epoxy coated reinforcing bars in superstructure elements other than
bridge decks. e.g. prestressed concrete beams.
- Increased clear cover for substructure elements. (i.e. bent caps,
abutments etc.)
- Stainless steel reinforcing
- Fiber Reinforced Polymer (FRP) reinforcing.
Concrete Deck Slabs on Stringers
Materials –
This map
[pdf, 1 page, 189 kb] shows areas of the state
where bridge decks are subjected regularly to deicing treatments.
Geometric Constraints – Deck slabs less than 8
in. thick are not recommended with TxDOT’s standard prestressed concrete
panels because they are not as durable or as constructible and they do
not provide enough practical room above a 4-in. panel.
Structural Analysis –
- Standard deck slab designs account for effects of a 2.5-in. asphaltic overlay
(DW). Weight of asphaltic overlay is based on a unit weight of 0.140 kcf <Table
3.5.1-1>.
- Live load is HL93 plus dynamic load allowance, IM.
- Account for extra concrete in permanent metal deck form flutes for custom deck
slab designs for which prestressed concrete panels cannot be used.
Design Criteria –
- Space deck slab main reinforcing steel (transverse reinforcement) no less than
6 in. to take advantage of reduced lap length requirements, as described in
<Article 5.11.2.1.3
- Make overhangs the same thickness as the slab unless other factors override
this preference. For example, use of HT railing requires a 10-in. overhang
thickness.
- See <Appendix A4: Table A4-1> for LL+IM moments for traditionally designed
deck slabs. TxDOT standard deck slab designs use this method.
- Take negative moment at 1/3 the flange width from beam centerline for concrete
I beams, and 1/4 the flange width from beam centerline for steel girders
<Article 4.6.2.1.6>.
- Empirical deck slab designs need not be analyzed unless torsionally stiff
girders are used <Commentary C9.7.2.4>.
- Effective slab width at transverse slab edges is approximately half the normal
effective slab width <Article 4.6.2.1.4c>. Standard thickened slab ends are
theoretically overstressed, but they have been experimentally proven to have
more than adequate strength.
- Standard deck slab designs are based on a crack width parameter, Z, of 130
kips/in. <Article 5.7.3.4>.
Software – No software is needed for the majority of
deck slabs. For special cases, use RISA 3D, any suitable finite element program,
or SLAB49.
Detailing –
- To account for reduced wheel load distribution at transverse slab edges,
strengthen the slab by increasing its depth, as shown on the
Thickened Slab End
Details standard drawing.
- The standard deck slab corner break dimension is 2 ft. 0 in when skew is more
than 15 degrees. The corner break point must occur at least 1 in. and preferably
3 in. from the toe of any concrete parapet into which an expansion joint is
upturned.
- With simple-span construction, minimize expansion joints by creating
multi-span units with the slab continuous over interior bents. At bents without
expansion joints, locate a control joint or construction joint in the deck.
- Distribution reinforcing steel in standard deck slabs, Bars D (bottom
longitudinal reinforcement), is based on <Article 9.7.3.2>.
- Additional longitudinal reinforcing steel is required for continuous steel
girders <Article 6.10.3.7>. Adding one #5 bar in the top slab between each usual
longitudinal bar meets this requirement.
Concrete Deck Slabs on U Beams (U40 and U54)
Structural Analysis – Consider using a normal
overhang when conditions make the sloped overhang unsightly or difficult and
expensive to construct. For the sloped overhang, the slope of the bottom face of
the overhang may vary significantly when used with curved slab edges primarily
because of the overhang distance varying along the length of the exterior U
beam. However, on a straight bridge slab edge, the slope of the bottom face of
the overhang varies only because of the vertical curvature of the roadway
surface and the camber and dead load deflection of the exterior U beam, thereby
creating a more pleasing appearance.
Prestressed Concrete I Beams and I Girders:
Materials –
Use a maximum concrete strength of 6.50 ksi release and 8.50 ksi for design.
Structural Analysis –
- You need not increase section properties of the beam to account for the
transformed area of strands or mild steel.
- For the calculation of live load distribution factors, modular ratio, n,
may conservatively be taken as 1.0.
Design Criteria–For grade separation structures, use the same beam depth for
the full length of structure for economies of scale and aesthetic reasons.
Stream crossing structures may have different types and sizes of beams for
purposes of economy. Optimize beam spacing in each span. Maintaining a constant
beam spacing for the full length of structure is not necessary. Selection of the
proper type beam for a span is a matter of economics; calculate relative costs
using current average bid prices for beams and slab.
Software – Use
PSTRS14, Version 4.0, for beam design. Use
this spreadsheet
[Excel, 155kb] to
calculate live load distribution factors.
Detailing – On the plans for each design, show optional design parameters for
maximum top flange stress, bottom flange stress, and ultimate moment due to all
design loads. The fabricator will retain the option to use other strand
arrangements, including straight strand patterns, stress relieved strand, or
0.6-in. diameter strand, if design parameters are satisfied by the prestress and
concrete strength selected.
Design Examples
Prestressed Concrete U Beams (Types U40 and U54)
Geometric Constraints –
- U beams are not vertical but are rotated to accommodate the average cross slope of a
given span. As a result, the depth of slab haunch at the left and right top
edges of the beam may differ. Pay special attention to these beams in
calculating the haunch values.
- The preferred method for framing U-beam centerlines is at the top of the beam.
This prevents spacing at the top of the beam from varying due to the cross
slope of the beam and, thus, simplifies slab formwork dimensions for
construction. Note beam spacings shown on the span details as being at the
top of the beam, and in beam spacings shown on the substructure details,
take into account the horizontal offset between the centerlines at the top
and bottom of the beam.
- The alternate method for framing U-beam centerlines is at the bottom of the
beam. This method allows the U beams to be framed as vertical members
whereby the beam spacings dimensioned on the span details and beam layouts
match the beam spacings shown on the substructure details. However, if this
method is used, call attention to the variable beam spacing at the top of
the beam in the plans. A construction note is recommended on the span
details stating, “Beam spacing shown is measured at bottom of beam. Beam
spacing at top of beam may vary due to cross slope of U beams.”
- TxDOT’s Bridge Division currently uses the Bridge Geometry System (BGS) software
program to frame U beams. The latest version of BGS frames U beams using the
alternate method. The BGS manual includes information on three framing
options written specifically for U beams: Options 20, 21, and 22. These
framing options help the designer calculate accurate slab haunch values,
bearing seat elevations, and bearing pad taper reports for U beams under the
alternate method.
- Use the same minimum haunch value for all U beams in a given span
if reasonable to do so.
- Left and right bearing seat elevations are located at the intersection of
the edges of bearing seats with centerline bearings. When calculating these
elevations for each beam seat, be careful to apply the appropriate deduction
at that elevation point—that is, the minimum deduction at the correct
elevation point and the maximum deduction at the other elevation point.
Typically, the minimum deduction and maximum deduction are each applied at
diagonally opposite corners of a beam in plan view. See
Prestressed
Concrete U Beam Design Guide for information on calculating U-beam slab haunches.
The information is tailored for use with BGS, but the principles behind the
method remain the same.
- Provide at
least 2 in. from the end of the cap or corbel to the edge of the bearing
seat.
-
Recommended Beam Spacings [pdf, 1 page, 52kb]
- Prestressed Concrete U Beam Design Guide [pdf,
13 pages, 247 kb]
Software – Use
PSTRS14,
Version 4.0, for beam design.
Use this
spreadsheet [Excel, 415kb] to calculate live load distribution factors.
Detailing –
- A full-depth cast-in-place deck with permanent metal deck forms may be
provided at the contractor’s option. This optional form is shown on the
Permanent Metal Deck Form standard drawing.
- Use thickened slab ends at all expansion joints with non-inverted tee bents. See
the Miscellaneous Slab Details
standard drawing for details of thickened slab ends.
- Do not show a detailed bill of reinforcing steel on production drawings. Instead, show a
table of bar designations with sizes used in the slab as is currently done
with I-beam structures. In addition, show a table of estimated quantities
with the total reinforcing steel based on 3.7 lbs. per sq. ft. of bridge
deck. This quantity includes the extra slab steel required over inverted-tee
bents and in thickened slab ends.
- If inverted-tee caps are used and are sloped to match the sloping face of the U
beam, use a 4:1 slope normal to the centerline of the bent.
- The actual cross slope of the U beams framing into the bent potentially complicates
construction of the bent cap and need not be considered. Try to extend the
ends of the inverted-tee bents about 6 in. past the bottom edge of the
exterior U beam. This extension allows for a more defined break between cap
and beams, and the contractor is unlikely to set the beams perfectly in line
with the end of the cap. The Miscellaneous Slab Details for Inverted-Tee
Bents standard drawings
show overhang details using this configuration
over the inverted-tee bent caps.
- Use slab dowels to provide lateral restraint when constructing U beams with
inverted-tee bents. These dowels are located at the top of the inverted-tee
stem and are in a slotted pipe to allow for expansion and contraction of the
unit. Typically, only one dowel is placed at the centerline of every beam 1
ft. from the centerline of the bent. Slab dowels need to be placed on only
one side of the centerline of the bent. The criteria for locating slab
dowels within units are similar to the method used for locating dowels
within concrete I-beam units.
- A left and right bearing seat elevation is given for each U-beam bearing seat location.
Bearing seats for U beams are level perpendicular to the centerline of the
bent but slop uniformly between the left and right bearing seat elevations.
This allows the bearing pads to taper in one direction.
- Include a Bearing Pad Taper Report sheet in the plans summarizing bearing pad tapers
to be used by the fabricator. See Appendix A of the
Bridge
Design Manual for information on the calculation of bearing pad
tapers for U beams.
Prestressed Slab Beams
Materials – Use a maximum concrete strength
of 6.75 ksi for release and 8.75 ksi for design. Design beams for
0.5-in. low-relaxation strands.
Geometric Constraints –
- Limit skew to 30 degrees. Larger skews may result in beam twist and uneven bearing on the pads.
- The requirement to bevel the bearing pads to match the beam slope on the
Elastomeric Bearing Details sheet will not result in parallel pad and beam surfaces for skewed bridges. The actual calculations and fabrication of pads for each particular skewed case is complex. Given the small area of the pads, experience with box beams and the nearly parallel surfaces, the pads should be able to deform sufficiently to accommodate the mismatches.
- When both a vertical curve and skew exist, a complex planar relationship develops between the skewed bottom of the slab beam, bearing pad, and bent or abutment cap: a stepped bearing seat arrangement on the caps is required.
- Except for the T411 and C411 railings, no adjustment is needed to individual reinforcing bars embedded into the slab beam to account for the effects of vertical curve. The vertical curve requires the slab to be thicker either at the ends of the beam or at midspan. Theoretically, each embedded bar should protrude from the beam a different amount. However, in the most extreme case (VC length = 600 ft., tangent slopes = -5%, 5%, and span length = 50 ft.), the maximum variation of the profile grade line from a straight line drawn between top of slab at adjacent bents is only 5/8 in. This is not significant enough to warrant complicating the detailing, fabrication, and installation of the railing reinforcing.
-
Recommended Span Lengths [pdf, 1 page, 9kb]
Prestressed Concrete Double-Tee Beams
Materials – Use a maximum concrete strength of 6.5 ksi
for release and 8.5 ksi for design.
Prestressed Concrete Box Beams (B20, B28, B34, and B40)
Materials – Use a maximum concrete strength of 6.50 ksi release and 8.50 ksi for
design.
Geometric Constraints –
- A three-pad system is currently used with box beams. Typically, the forward
station end of the beam sits on a single elastomeric bearing pad while the back
station end sits on two smaller pads.
- Box beams are fabricated using a two-stage monolithic casting. The bottom slab
is cast in the first stage, and the sides and top are cast in the second stage
while the slab concrete is still plastic. In addition, cardboard void forms are
no longer permitted. All interior voids must be formed with polystyrene. Void
drain holes are installed at the corners of the bottom slab during fabrication.
Design Criteria –
- Standard drawings do not support spread box beam configurations.
- Use a cast-in-place reinforced concrete slab rather than an ACP overlay on box
beam bridges. The slab should have a 5-in. minimum thickness, typically at the
center of the span (or at center of bearing in situations such as sag vertical
curves).
- Avoid slab overhangs. Choose box beams and gap sizes so that the edge of the
slab corresponds to the edge of the top flange of the exterior beams.
- Box beams are not appropriate for use on curved structures and should be
avoided on flared structures. The complexity of the geometry required to frame
the bridge increases dramatically as the degree of curvature exceeds 1 or 2
degrees.
- Use 5-ft. boxes as exterior beams when the roadway width requires a
combination of both 4-ft. and 5-ft. boxes.
- Do not use dowels for lateral restraint. Provide lateral restraint by
12-in.wide by 7-in. tall ear walls located at the ends of each abutment and
interior bent cap. Provide a 1/2-in. gap between the the ear wall and the
outside edge of the exterior beam.
- Provide longitudinal restraint at interior bents only when a continuous unit
exceeds four spans in length, or when the beam grade exceeds 6%. Provide
longitudinal restraint at interior bents only.
- Use beam hold-downs at water crossings when the superstructure could be
subjected to pressure flow. The hold-downs are typically placed at the center of
the joint between the exterior beam and the first interior beam on both sides of
the structure. The hold-downs may be moved to the second interior joint for
heavily skewed bridges (approximately 25 to 30 degrees). A minimum gap of 1.5
in. is required at a joint where a hold-down is located.
- Bearing seats are not used with box beams. The pads sit directly on top of the
cap. Provide top-of-cap elevations at the points coinciding with the outer edge
of the exterior boxes at the centerline of bearing. Also provide elevations at
any intermediate points along the cap, at the centerline of bearing, where
either a change in cap slope or change in cap elevation occurs.
- Box beams are not vertical but either parallel the roadway surface when the
cross slope is constant or are rotated to the average cross slope of a span in a
transition area. Because there are no bearing seat build-ups, the top of the cap
must be sloped to match the rotation of the beams.
- Provide a minimum of three elevation points for unskewed spans with an even
number of box beams and a constant housetop profile: one at the outside edge of
each of the exterior beams and a third point at the center of the middle joint.
Provide four elevation points for spans with an odd number of beams: one at the
outside edge of each exterior beam and one at the center of each joint on either
side of the middle beam.
- Framing is complicated in cross-slope transition areas and skewed bridges.
Orient the beams to minimize the variation in slab thickness both longitudinally
and transversely along the span. This may require stepping the cap at some
joints so that adjacent beams not only have a different slope but also sit at a
different elevation. Elevation points may be required as often as every joint in
some situations. The forward half of an interior bent cap may have a different
elevation than the back half at some locations.
-
Recommended Span Lengths [pdf, 1 page, 11kb]