COUNTY: ROCKWALL HIGHWAY: FM 549, ETCLENGTH: 9.2040MI CONTROL NUMBER: 1091-04-022, ETCDBE GOAL: 6.5 % PROJECT NUMBER: STP 1702(454) TYPE: WDN, STR, REMX, OL, PV MRKS, SIGNS TIME FOR COMPLETION: 508 WORKING DAYSGUARANTY: 100,000.00 BIDS RECEIVED UNTIL: 1:00 PM JULY 12, 2017*EST.COST: 13,228,931.39 BIDS WILL BE OPENED: 1:00 PM JULY 12, 2017 MAIL OR DELIVER BIDS TO: FOR PS&E PROJECT QUESTIONS CALL: TEXAS DEPARTMENT OF TRANSPORTATIONJEFFREY BUSH P.E. ATTN: CONSTRUCTION DIVISION - ROOM 1A.2 2750 S WASHINGTON ST 200 E RIVERSIDEKAUFMAN, TX 75142 AUSTIN TX 78704-1204972/962-3617 TO REQUEST A PROPOSAL CALL 512/416-2498 FOR ELECTRONIC BIDDING VISIT THE WEBSITE BELOW: http://www.txdot.gov/business/letting-bids/ebs.html ------------------------------------------------------------------------------ COUNTY CONTROL LIMITS FROM HIGHWAY PROJECT LIMITS TO ------------------------------------------------------------------------------ ROCKWALL1091-04-022EAST OF FM 550 FM 549STP 1702(454)WEST OF SH 205 LENGTH: 3.3520 MILES ROCKWALL3148-01-009AT COUNTRY CLUB DR FM 3097STP 1702(454). LENGTH: 0.3560 MILES ROCKWALL1014-03-059EAST OF FM 549 FM 550STP 1702(454)SH 205 LENGTH: 5.4960 MILES ------------------------------------------------------------------------------------------------------------- ITEM DESAPPROXIMATE ALT NO. CD. ITEM DESCRIPTIONUNITQUANTITIESBID PRICEAMOUNTSEQ ------------------------------------------------------------------------------------------------------------- 100 6002PREPARING ROWSTA 449.9801 104 6017REMOVING CONC (DRIVEWAYS)SY 5,290.0002 104 6032REMOVING CONC (WHEELCHAIR RAMP)SY 52.0003 105 6011REMOVING STAB BASE AND ASPH PAV (2"-6")SY 5,984.0004 105 6013REMOVING STAB BASE & ASPH PAV (9")SY 6,600.0005 105 6085REMOVING STAB BASE & ASPH PAV (0-19 IN)SY 2,611.0006 110 6001EXCAVATION (ROADWAY)CY 1,511.0007 112 6001SUBGRADE WIDENING (ORD COMP)STA 449.9808 132 6006EMBANKMENT (FINAL)(DENS CONT)(TY C)CY 44,636.2009 134 6004BACKFILL (TY A OR B)STA 449.98010 152 6001ROAD GRADER WORK (ORD COMP)STA 449.98011 164 6035DRILL SEEDING (PERM) (RURAL) (CLAY)SY 174,198.00012 164 6051DRILL SEED (TEMP)(WARM OR COOL)SY 82,085.00013 168 6001VEGETATIVE WATERINGMG 68,988.00014 247 6073FL BS (CMP IN PLC)(TY D GR 1-2) (6")SY 2,250.00015 247 6133FL BS (RDWY DEL) (TY D GR 1-2)TON 19,613.63016 247 6254FL BS (CMP IN PLC)(TY-D GR-1-2)(14")SY 3,185.00017 247 6304FL BS (CMP IN PLACE) (TY D GR 1-2)(10")SY 51,412.44018 247 6477FL BS (CMP IN PLC)(TY D GR 1-2)(16")SY 8,399.99019 247 6478FL BS (CMP IN PLC)(TY D GR1-2)(13")SY 84,718.00020 251 6034REWORK BS MTL (TY C) (8") (ORD COMP)SY 66,694.00021 251 6035REWORK BS MTL (TY C) (6") (DENS CONT)SY 41,413.00022 275 6001CEMENTTON 838.40023 275 6004CEMENT TREAT (MX EXST MTL & NW BS) (6")SY 138,664.24024 314 6021EMULS ASPH (PRIME)(MS-2 OR SS-1)GAL 29,995.43025 316 6024ASPH (CRS-2P)GAL 51,877.04026 316 6029ASPH (RC-250)GAL 32,206.04027 316 6403AGGR (TY-B GR-5 OR TY-L GR-5)CY 1,082.07028 316 6419ASPH (AC-15P, AC-20-5TR OR AC-20XP)GAL 43,976.04029 316 6440AGGR (TY-B GR-3 OR TY-L GR-3)(SAC-B)CY 1,102.07030 344 6011SUPERPAVE MIXTURES SP-B PG64-22TON 990.00031 344 6106SUPERPAVE MIXTURES SP-D PG64-22TON 14,513.50032 351 6008FLEXIBLE PAVEMENT STRUCTURE REPAIR(12")SY 3,666.50033 354 6057PLANE ASPH CONC PAV (4")SY 46,164.00034 354 6152PLANE ASPH CONC PAV (9")SY 48,013.79035 400 6005CEM STABIL BKFLCY 6.50036 400 6008CUT & RESTORE ASPH PAVINGSY 73.00037 402 6001TRENCH EXCAVATION PROTECTIONLF 125.00038 403 6001TEMPORARY SPL SHORINGSF 2,500.00039 416 6032DRILL SHAFT (TRF SIG POLE) (36 IN)LF 60.00040 432 6001RIPRAP (CONC)(4 IN)CY 123.35041 432 6002RIPRAP (CONC)(5 IN)CY 20.50042 432 6045RIPRAP (MOW STRIP)(4 IN)CY 63.00043 462 6052CONC BOX CULV (5 FT X 4 FT)(EXTEND)LF 54.00044 462 6054CONC BOX CULV (6 FT X 3 FT)(EXTEND)LF 13.00045 462 6055CONC BOX CULV (6 FT X 4 FT)(EXTEND)LF 29.00046 464 6001RC PIPE (CL III)(12 IN)LF 184.00047 464 6003RC PIPE (CL III)(18 IN)LF 2,598.00048 464 6005RC PIPE (CL III)(24 IN)LF 1,263.00049 464 6007RC PIPE (CL III)(30 IN)LF 276.00050 464 6008RC PIPE (CL III)(36 IN)LF 50.00051 464 6009RC PIPE (CL III)(42 IN)LF 16.00052 464 6010RC PIPE (CL III)(48 IN)LF 110.00053 464 6012RC PIPE (CL III)(60 IN)LF 52.00054 466 6005HEADWALL (CH - FW - 0) (DIA= 24 IN)EA 2.00055 466 6007HEADWALL (CH - FW - 0) (DIA= 30 IN)EA 3.00056 466 6009HEADWALL (CH - FW - 0) (DIA= 36 IN)EA 1.00057 466 6025HEADWALL (CH - FW - 15) (DIA= 42 IN)EA 1.00058 466 6026HEADWALL (CH - FW - 15) (DIA= 48 IN)EA 2.00059 466 6052HEADWALL (CH - FW - 45) (DIA= 30 IN)EA 1.00060 466 6101HEADWALL (CH - PW - 0) (DIA= 36 IN)EA 1.00061 466 6103HEADWALL (CH - PW - 0) (DIA= 48 IN)EA 3.00062 466 6135HEADWALL (CH - PW - S) (DIA= 42 IN)EA 2.00063 466 6152WINGWALL (FW - 0) (HW=5 FT)EA 4.00064 466 6207WINGWALL (SW - 0) (HW=4 FT)EA 2.00065 467 6008SET (TY I) (30 IN) (3: 1) (C)EA 2.00066 467 6014SET (TY I) (36 IN) (3: 1) (C)EA 4.00067 467 6018SET (TY I) (42 IN) (3: 1) (C)EA 2.00068 467 6021SET (TY I) (48 IN) (3: 1) (C)EA 1.00069 467 6326SET (TY II) (12 IN) (RCP) (6: 1) (P)EA 8.00070 467 6363SET (TY II) (18 IN) (RCP) (6: 1) (P)EA 122.00071 467 6395SET (TY II) (24 IN) (RCP) (6: 1) (P)EA 68.00072 467 6423SET (TY II) (30 IN) (RCP) (6: 1) (P)EA 6.00073 467 6480SET (TY II) (48 IN) (RCP) (6: 1) (P)EA 2.00074 480 6001CLEAN EXIST CULVERTSEA 20.00075 496 6004REMOV STR (SET)EA 124.00076 496 6005REMOV STR (WINGWALL)EA 8.00077 496 6006REMOV STR (HEADWALL)EA 16.00078 496 6007REMOV STR (PIPE)LF 1,491.00079 496 6016REMOV STR (PIPE)EA 5.00080 496 6050REMOV STR (DRIVEWAY CULVERT)EA 61.00081 500 6001MOBILIZATIONLS 1.00082 502 6001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO 25.00083 506 6002ROCK FILTER DAMS (INSTALL) (TY 2)LF 1,120.00084 506 6011ROCK FILTER DAMS (REMOVE)LF 1,120.00085 506 6020CONSTRUCTION EXITS (INSTALL) (TY 1)SY 612.00086 506 6024CONSTRUCTION EXITS (REMOVE)SY 612.00087 506 6038TEMP SEDMT CONT FENCE (INSTALL)LF 4,765.00088 506 6039TEMP SEDMT CONT FENCE (REMOVE)LF 4,765.00089 506 6041BIODEG EROSN CONT LOGS (INSTL) (12")LF 2,113.00090 506 6043BIODEG EROSN CONT LOGS (REMOVE)LF 2,113.00091 508 6001CONSTRUCTING DETOURSSY 900.00092 530 6004DRIVEWAYS (CONC)SY 4,718.00093 530 6005DRIVEWAYS (ACP)SY 5,458.00094 530 6016 DRIVEWAYS (BASE)SY 1,685.00095 530 6017DRIVEWAYS (CONC) (HES)SY 2,050.00096 531 6008CURB RAMPS (TY 5)EA 4.00097 540 6001MTL W-BEAM GD FEN (TIM POST)LF 1,345.00098 542 6001REMOVE METAL BEAM GUARD FENCELF 575.00099 544 6001GUARDRAIL END TREATMENT (INSTALL)EA 10.000100 544 6003GUARDRAIL END TREATMENT (REMOVE)EA 2.000101 560 6011MAILBOX INSTALL-S (TWW-POST) TY 4EA 61.000102 560 6013MAILBOX INSTALL-M (TWW-POST) TY 4EA 6.000103 618 6023CONDT (PVC) (SCH 40) (2")LF 11.000104 618 6029CONDT (PVC) (SCH 40) (3")LF 40.000105 618 6046CONDT (PVC) (SCH 80) (2")LF 17.000106 620 6008ELEC CONDR (NO.8) INSULATEDLF 788.000107 620 6009ELEC CONDR (NO.6) BARELF 39.000108 620 6010ELEC CONDR (NO.6) INSULATEDLF 484.000109 624 6002GROUND BOX TY A (122311)W/APRONEA 2.000110 624 6008GROUND BOX TY C (162911)W/APRONEA 1.000111 625 6002ZINC-COAT STL WIRE STRAND (3/16")LF 716.000112 625 6004ZINC-COAT STL WIRE STRAND (5/16")LF 837.000113 628 6187ELC SRV TY D 120/240 070(NS)SS(E)PS(U)EA 1.000114 644 6001IN SM RD SN SUP&AM TY10BWG(1)SA(P)EA 66.000115 644 6030IN SM RD SN SUP&AM TYS80(1)SA(T)EA 2.000116 644 6033IN SM RD SN SUP&AM TYS80(1)SA(U)EA 2.000117 658 6002INSTL DEL ASSM (D-SW)SZ 1(FLX)GND(BI)EA 16.000118 658 6048INSTL OM ASSM (OM-2Z)(FLX)GNDEA 24.000119 662 6111WK ZN PAV MRK SHT TERM (TAB)TY Y-2EA 8,464.000120 666 6036REFL PAV MRK TY I (W)8"(SLD)(100MIL)LF 1,243.000121 666 6042REFL PAV MRK TY I (W)12"(SLD)(100MIL)LF 450.000122 666 6048REFL PAV MRK TY I (W)24"(SLD)(100MIL)LF 142.000123 666 6054REFL PAV MRK TY I (W)(ARROW)(100MIL)EA 10.000124 666 6078REFL PAV MRK TY I (W)(WORD)(100MIL)EA 9.000125 666 6141REFL PAV MRK TY I (Y)12"(SLD)(100MIL)LF 351.000126 666 6224PAVEMENT SEALER 4"LF 86.000127 666 6226PAVEMENT SEALER 8"LF 100.000128 666 6230PAVEMENT SEALER 24"LF 66.000129 666 6231PAVEMENT SEALER (ARROW)EA 2.000130 666 6232PAVEMENT SEALER (WORD)EA 2.000131 666 6303RE PM W/RET REQ TY I (W)4"(SLD)(100MIL)LF 95,612.000132 666 6308RE PM W/RET REQ TY I (W)6"(SLD)(090MIL)LF 24.000133 666 6312RE PM W/RET REQ TY I (Y)4"(BRK)(100MIL)LF 3,270.000134 666 6315RE PM W/RET REQ TY I (Y)4"(SLD)(100MIL)LF 81,556.000135 668 6076PREFAB PAV MRK TY C (W) (24") (SLD)LF 66.000136 668 6077PREFAB PAV MRK TY C (W) (ARROW)EA 2.000137 668 6085PREFAB PAV MRK TY C (W) (WORD)EA 2.000138 672 6007REFL PAV MRKR TY I-CEA 101.000139 672 6009REFL PAV MRKR TY II-A-AEA 89.000140 672 6013TRAFFIC BUTTON TY II-A-AEA 1,639.000141 678 6001PAV SURF PREP FOR MRK (4")LF 86.000142 678 6004PAV SURF PREP FOR MRK (8")LF 100.000143 678 6008PAV SURF PREP FOR MRK (24")LF 66.000144 678 6009PAV SURF PREP FOR MRK (ARROW)EA 2.000145 678 6016PAV SURF PREP FOR MRK (WORD)EA 2.000146 680 6002INSTALL HWY TRF SIG (ISOLATED)EA 1.000147 682 6001VEH SIG SEC (12")LED(GRN)EA 8.000148 682 6002VEH SIG SEC (12")LED(GRN ARW)EA 3.000149 682 6003VEH SIG SEC (12")LED(YEL)EA 8.000150 682 6004VEH SIG SEC (12")LED(YEL ARW)EA 2.000151 682 6005VEH SIG SEC (12")LED(RED)EA 8.000152 682 6006VEH SIG SEC (12")LED(RED ARW)EA 2.000153 682 6035BACK PLATE (12")(3 SEC)(VENTED)ALUMEA 6.000154 682 6036BACK PLATE (12")(4 SEC)(VENTED)ALUMEA 2.000155 682 6037BACK PLATE (12")(5 SEC)(VENTED)ALUMEA 1.000156 684 6036TRF SIG CBL (TY A)(14 AWG)(10 CONDR)LF 515.000157 686 6020INS TRF SIG PL AM (S)STR(TY D)LUMEA 4.000158 730 6107FULL - WIDTH MOWINGCYC 4.000159 60016002PORTABLE CHANGEABLE MESSAGE SIGNEA 6.000160 60256001RADAR PRESENCE DETECTOREA 4.000161 60256002RADAR PRESENCE DETECTOR COMM CABLELF 459.000162 60546001SPREAD SPECTRUM RADIOEA 2.000163 60546002COAXIAL CABLELF 43.000164 60546004ANTENNA (OMNI-DIRECTIONAL)EA 1.000165 60546005ANTENNA (UNI-DIRECTIONAL)EA 2.000166 60586001BBU SYSTEM (EXTERNAL BATT CABINET)EA 1.000167 61556001RADAR DETECTOREA 2.000168 61556002RADAR COMMUNICATION CABLELF 241.000169 * INCLUDES FORCE ACCOUNT WORK AMOUNTS AS FOLLOWS: MATERIAL FURNISHED BY THE STATE (PART) $12,000.00 PUBLIC UTIL. FORCE ACCT WORK(PART) $3,000.00 CONTRACTOR FORCE ACCOUNT WORK (PART) $20,000.00 CONTRACTOR FORCE ACCOUNT WORK (PART) $21,000.00