Tabulation of Bids for Project STP 2017(644)
Text version of this page | |||
County: | HOUSTON | Let Date: | 02/02/17 |
Type: | RECONSTRUCT AND WIDEN PAVEMENT | Seq No: | 3046 |
Time: | 166 WORKING DAYS | Project ID: | STP 2017(644) |
Highway: | FM 227 | Contract #: | 02173046 |
Length: | 3.928 | CCSJ: | 0937-02-033 |
Limits: | |||
From: | 0.5 MI E OF CR 1685 | Check: | $68,000.000 |
To: | Misc Cost: | $7,500.000 |
Estimate | $3,391,417.00 | % Over/Under | Company |
Bidder 1 | $3,134,729.03 | -7.57% | PINTO CONSTRUCTION CO., INC. |
Bidder 2 | $3,242,867.68 | -4.38% | A. L. HELMCAMP, INC. |
Bidder 3 | $3,524,394.67 | +3.92% | DREWERY CONSTRUCTION COMPANY, INCORPORATED |
Bidder 4 | $3,575,266.04 | +5.42% | L. S. EQUIPMENT CO., INC. |
Bidder 5 | $3,685,214.35 | +8.66% | LONGVIEW BRIDGE AND ROAD, LTD. |
Item Code | Description | Unit | Quantity | Unit Est. | Bidder | Unit Bid |
1006002 | PREPARING ROW | STA | 207.000 | 750.000 | 1 2 3 4 5 | 1,205.000 1,200.000 1,000.000 1,000.000 1,500.000 |
1126001 | SUBGRADE WIDENING (ORD COMP) | STA | 205.290 | 200.000 | 1 2 3 4 5 | 168.290 100.000 165.000 400.000 450.000 |
1326019 | EMBANKMENT (VEHICLE)(ORD COMP)(TY B) | CY | 2,468.000 | 30.000 | 1 2 3 4 5 | 17.800 19.000 23.000 12.000 11.000 |
1346002 | BACKFILL (TY B) | STA | 175.350 | 155.000 | 1 2 3 4 5 | 154.150 300.000 145.000 200.000 160.000 |
1586003 | SPEC EXCAV WORK (HYD EXCAVATOR) | HR | 64.000 | 100.000 | 1 2 3 4 5 | 24.150 82.000 175.000 75.000 175.000 |
1626002 | BLOCK SODDING | SY | 2,883.000 | 5.000 | 1 2 3 4 5 | 6.300 3.000 5.250 4.000 10.000 |
1646009 | BROADCAST SEED (TEMP) (WARM) | SY | 61,000.000 | 0.150 | 1 2 3 4 5 | 0.100 0.060 0.130 0.120 0.170 |
1646011 | BROADCAST SEED (TEMP) (COOL) | SY | 61,000.000 | 0.150 | 1 2 3 4 5 | 0.100 0.060 0.130 0.120 0.170 |
1646021 | CELL FBR MLCH SEED(PERM)(RURAL)(SANDY) | SY | 122,000.000 | 0.250 | 1 2 3 4 5 | 0.250 0.230 0.260 0.500 0.350 |
1686001 | VEGETATIVE WATERING | MG | 1,247.400 | 15.000 | 1 2 3 4 5 | 0.010 10.000 15.000 1.000 30.000 |
1696004 | SOIL RETENTION BLANKETS (CL 1) (TY D) | SY | 540.000 | 2.000 | 1 2 3 4 5 | 1.500 3.500 1.050 3.000 1.400 |
2046003 | SPRINKLING (DUST CONTROL) | MG | 282.000 | 2.000 | 1 2 3 4 5 | 0.010 18.000 16.000 1.000 0.010 |
2476121 | FL BS (RDWY DEL) (TY A GR 1-2) | TON | 20,558.200 | 40.000 | 1 2 3 4 5 | 36.120 30.000 34.000 39.000 26.000 |
2756001 | CEMENT | TON | 982.000 | 140.000 | 1 2 3 4 5 | 132.000 142.000 154.250 150.000 180.000 |
2756023 | CEMENT TREAT(MX EXST MTL & NW BS)(12") | SY | 56,163.000 | 3.000 | 1 2 3 4 5 | 2.710 3.200 3.150 3.500 3.000 |
3166029 | ASPH (RC-250) | GAL | 14,041.000 | 4.000 | 1 2 3 4 5 | 3.550 4.500 3.550 4.000 4.100 |
3166400 | ASPH (AC-15P OR AC-10-2TR OR CRS-2P) | GAL | 50,733.000 | 3.000 | 1 2 3 4 5 | 2.800 3.000 2.700 3.000 3.500 |
3166402 | AGGR (TY-PE, E, L OR PL GR 3) | CY | 626.000 | 120.000 | 1 2 3 4 5 | 91.900 150.000 125.000 125.000 150.000 |
3166417 | AGGR (TY E OR L GR 5) | CY | 433.000 | 120.000 | 1 2 3 4 5 | 98.260 250.000 160.000 150.000 185.000 |
3166433 | AGGR(TY PE,TY-PL,TY-E,TY-L GR-4)(SAC-B) | CY | 512.000 | 120.000 | 1 2 3 4 5 | 112.300 100.000 126.000 125.000 145.000 |
3406270001 | D-GR HMA(SQ) TY-D PG64-22 NON-MOW STRIP | SY | 1,534.000 | 40.000 | 1 2 3 4 5 | 34.020 35.000 45.000 35.000 44.000 |
4006005 | CEM STABIL BKFL | CY | 13.000 | 160.000 | 1 2 3 4 5 | 187.950 185.000 200.000 175.000 230.000 |
4006007 | CUT & RESTORE CONC PAVING | SY | 6.000 | 150.000 | 1 2 3 4 5 | 102.900 100.000 235.000 250.000 300.000 |
4006008 | CUT & RESTORE ASPH PAVING | SY | 350.000 | 120.000 | 1 2 3 4 5 | 91.350 90.000 68.000 120.000 65.000 |
4006012 | CUT AND RESTORE PAV (FLEX BASE) | SY | 155.000 | 50.000 | 1 2 3 4 5 | 47.250 52.000 51.000 50.000 30.000 |
4206009 | CL A CONC (COLLAR) | EA | 9.000 | 1,000.000 | 1 2 3 4 5 | 840.000 680.000 1,100.000 900.000 1,100.000 |
4326024 | RIPRAP (STONE COMMON)(DRY)(12 IN) | CY | 44.000 | 180.000 | 1 2 3 4 5 | 207.900 180.000 215.000 200.000 205.000 |
4516019 | RETROFIT RAIL (TY T631) | LF | 273.000 | 110.000 | 1 2 3 4 5 | 64.580 65.000 56.000 85.000 135.000 |
4646003 | RC PIPE (CL III)(18 IN) | LF | 2,135.000 | 40.000 | 1 2 3 4 5 | 46.200 47.000 50.000 50.000 42.000 |
4646005 | RC PIPE (CL III)(24 IN) | LF | 238.000 | 60.000 | 1 2 3 4 5 | 79.800 75.000 70.000 75.000 54.000 |
4646007 | RC PIPE (CL III)(30 IN) | LF | 60.000 | 90.000 | 1 2 3 4 5 | 115.500 152.000 100.000 100.000 120.000 |
4666037 | HEADWALL (CH - FW - 30) (DIA= 30 IN) | EA | 1.000 | 4,000.000 | 1 2 3 4 5 | 5,512.500 5,300.000 4,100.000 5,000.000 3,500.000 |
4666039 | HEADWALL (CH - FW - 30) (DIA= 36 IN) | EA | 2.000 | 4,800.000 | 1 2 3 4 5 | 6,142.500 5,800.000 5,100.000 6,500.000 4,900.000 |
4666040 | HEADWALL (CH - FW - 30) (DIA= 42 IN) | EA | 1.000 | 5,500.000 | 1 2 3 4 5 | 7,192.500 6,800.000 6,900.000 8,000.000 6,250.000 |
4666097 | HEADWALL (CH - PW - 0) (DIA= 24 IN) | EA | 6.000 | 4,000.000 | 1 2 3 4 5 | 5,460.000 5,300.000 4,900.000 4,500.000 4,400.000 |
4666099 | HEADWALL (CH - PW - 0) (DIA= 30 IN) | EA | 2.000 | 4,800.000 | 1 2 3 4 5 | 5,670.000 5,400.000 6,700.000 5,000.000 6,800.000 |
4666101 | HEADWALL (CH - PW - 0) (DIA= 36 IN) | EA | 5.000 | 5,500.000 | 1 2 3 4 5 | 6,510.000 6,200.000 7,800.000 5,800.000 8,600.000 |
4666105 | HEADWALL (CH - PW - 0) (DIA= 60 IN) | EA | 1.000 | 10,000.000 | 1 2 3 4 5 | 14,175.000 15,000.000 15,000.000 13,000.000 18,150.000 |
4666130 | HEADWALL (CH - PW - S) (DIA= 24 IN) | EA | 1.000 | 5,000.000 | 1 2 3 4 5 | 5,565.000 5,300.000 5,200.000 5,000.000 4,820.000 |
4666132 | HEADWALL (CH - PW - S) (DIA= 30 IN) | EA | 1.000 | 5,500.000 | 1 2 3 4 5 | 6,090.000 5,800.000 6,300.000 6,000.000 5,720.000 |
4666134 | HEADWALL (CH - PW - S) (DIA= 36 IN) | EA | 1.000 | 5,900.000 | 1 2 3 4 5 | 6,930.000 6,300.000 8,300.000 6,500.000 9,120.000 |
4666140 | HEADWALL (CH - PW - S) (DIA= 72 IN) | EA | 1.000 | 17,500.000 | 1 2 3 4 5 | 17,325.000 17,800.000 21,000.000 17,000.000 28,000.000 |
4676149 | SET (TY I)(S= 4 FT)(HW= 5 FT)(3:1) (P) | EA | 1.000 | 8,000.000 | 1 2 3 4 5 | 9,922.500 11,000.000 8,600.000 10,000.000 8,220.000 |
4676358 | SET (TY II) (18 IN) (RCP) (4: 1) (C) | EA | 6.000 | 525.000 | 1 2 3 4 5 | 630.000 660.000 590.000 600.000 560.000 |
4676363 | SET (TY II) (18 IN) (RCP) (6: 1) (P) | EA | 186.000 | 650.000 | 1 2 3 4 5 | 630.000 680.000 670.000 600.000 640.000 |
4676388 | SET (TY II) (24 IN) (RCP) (3: 1) (C) | EA | 1.000 | 650.000 | 1 2 3 4 5 | 735.000 750.000 680.000 850.000 720.000 |
4676390 | SET (TY II) (24 IN) (RCP) (4: 1) (C) | EA | 8.000 | 725.000 | 1 2 3 4 5 | 850.500 890.000 790.000 900.000 825.000 |
4676395 | SET (TY II) (24 IN) (RCP) (6: 1) (P) | EA | 12.000 | 750.000 | 1 2 3 4 5 | 997.500 1,100.000 1,000.000 1,000.000 1,035.000 |
4676417 | SET (TY II) (30 IN) (RCP) (3: 1) (C) | EA | 2.000 | 950.000 | 1 2 3 4 5 | 1,039.500 900.000 1,200.000 1,500.000 1,140.000 |
4676419 | SET (TY II) (30 IN) (RCP) (4: 1) (C) | EA | 10.000 | 1,200.000 | 1 2 3 4 5 | 1,522.500 1,350.000 1,200.000 1,600.000 1,315.000 |
4676423 | SET (TY II) (30 IN) (RCP) (6: 1) (P) | EA | 2.000 | 1,800.000 | 1 2 3 4 5 | 1,758.750 1,550.000 1,500.000 2,000.000 1,720.000 |
4806001 | CLEAN EXIST CULVERTS | EA | 4.000 | 800.000 | 1 2 3 4 5 | 945.000 470.000 1,500.000 1,000.000 1,010.000 |
4966016 | REMOV STR (PIPE) | EA | 87.000 | 200.000 | 1 2 3 4 5 | 278.250 260.000 220.000 300.000 400.000 |
5006001 | MOBILIZATION | LS | 1.000 | 310,000.000 | 1 2 3 4 5 | 205,000.000 230,000.000 425,000.000 340,000.000 350,000.000 |
5026001 | BARRICADES, SIGNS AND TRAFFIC HANDLING | MO | 14.000 | 2,500.000 | 1 2 3 4 5 | 1,657.500 6,200.000 1,935.000 3,000.000 2,200.000 |
5066002003 | ROCK FILTER DAMS (INSTALL) (TY 2) | LF | 2,520.000 | 30.000 | 1 2 3 4 5 | 31.000 30.000 31.000 30.000 30.000 |
5066011003 | ROCK FILTER DAMS (REMOVE) | LF | 2,520.000 | 5.000 | 1 2 3 4 5 | 8.500 3.000 8.400 6.000 10.000 |
5066020003 | CONSTRUCTION EXITS (INSTALL) (TY 1) | SY | 222.000 | 20.000 | 1 2 3 4 5 | 30.000 11.000 31.500 30.000 51.000 |
5066024003 | CONSTRUCTION EXITS (REMOVE) | SY | 222.000 | 10.000 | 1 2 3 4 5 | 7.000 2.000 7.350 5.000 10.000 |
5066038003 | TEMP SEDMT CONT FENCE (INSTALL) | LF | 16,923.000 | 2.500 | 1 2 3 4 5 | 3.000 2.500 2.600 3.000 3.300 |
5066039003 | TEMP SEDMT CONT FENCE (REMOVE) | LF | 16,923.000 | 1.000 | 1 2 3 4 5 | 1.000 0.400 0.800 1.000 1.000 |
5306005 | DRIVEWAYS (ACP) | SY | 170.000 | 40.000 | 1 2 3 4 5 | 32.250 50.000 92.500 50.000 70.000 |
5306006 | DRIVEWAYS (SURF TREAT) | SY | 630.000 | 25.000 | 1 2 3 4 5 | 32.250 20.000 57.500 50.000 70.000 |
5306009 | TURNOUTS (SURF TREAT) | SY | 93.000 | 25.000 | 1 2 3 4 5 | 32.250 30.000 61.000 50.000 125.000 |
5406001 | MTL W-BEAM GD FEN (TIM POST) | LF | 2,127.000 | 20.000 | 1 2 3 4 5 | 18.900 19.000 19.000 20.000 25.000 |
5406006 | MTL BEAM GD FEN TRANS (THRIE-BEAM) | EA | 4.000 | 1,500.000 | 1 2 3 4 5 | 1,312.500 1,300.000 2,900.000 1,300.000 1,725.000 |
5406017 | MTL BM GD FEN (LONG SPAN SYSTEM) | LF | 300.000 | 35.000 | 1 2 3 4 5 | 31.500 32.000 31.500 19.000 41.000 |
5426001 | REMOVE METAL BEAM GUARD FENCE | LF | 2,650.000 | 5.000 | 1 2 3 4 5 | 2.630 2.600 3.600 5.000 3.450 |
5426002 | REMOVE TERMINAL ANCHOR SECTION | EA | 24.000 | 150.000 | 1 2 3 4 5 | 157.500 160.000 180.000 200.000 207.000 |
5426004 | RM MTL BM GD FENCE TRANS (THRIE-BEAM) | EA | 4.000 | 170.000 | 1 2 3 4 5 | 157.500 160.000 265.000 200.000 207.000 |
5446001 | GUARDRAIL END TREATMENT (INSTALL) | EA | 24.000 | 2,200.000 | 1 2 3 4 5 | 2,152.500 2,200.000 2,150.000 2,250.000 2,830.000 |
5606007 | MAILBOX INSTALL-S (WC-POST) TY 3 | EA | 1.000 | 170.000 | 1 2 3 4 5 | 183.750 190.000 173.000 250.000 228.000 |
5606008 | MAILBOX INSTALL-D (WC-POST) TY 3 | EA | 1.000 | 170.000 | 1 2 3 4 5 | 183.750 200.000 173.000 300.000 228.000 |
6446001 | IN SM RD SN SUP&AM TY10BWG(1)SA(P) | EA | 2.000 | 440.000 | 1 2 3 4 5 | 444.150 450.000 444.000 500.000 585.000 |
6446007 | IN SM RD SN SUP&AM TY10BWG(1)SA(U) | EA | 2.000 | 600.000 | 1 2 3 4 5 | 572.250 570.000 572.000 525.000 750.000 |
6446027 | IN SM RD SN SUP&AM TYS80(1)SA(P) | EA | 1.000 | 500.000 | 1 2 3 4 5 | 685.650 690.000 685.000 650.000 900.000 |
6446030 | IN SM RD SN SUP&AM TYS80(1)SA(T) | EA | 5.000 | 750.000 | 1 2 3 4 5 | 648.900 650.000 650.000 650.000 850.000 |
6446060 | IN SM RD SN SUP&AM TYTWT(1)WS(P) | EA | 13.000 | 260.000 | 1 2 3 4 5 | 281.400 280.000 280.000 325.000 370.000 |
6446061 | IN SM RD SN SUP&AM TYTWT(1)WS(T) | EA | 4.000 | 350.000 | 1 2 3 4 5 | 309.750 310.000 310.000 350.000 400.000 |
6446076 | REMOVE SM RD SN SUP&AM | EA | 28.000 | 80.000 | 1 2 3 4 5 | 78.750 80.000 80.000 100.000 100.000 |
6586014 | INSTL DEL ASSM (D-SW)SZ (BRF)CTB (BI) | EA | 2.000 | 35.000 | 1 2 3 4 5 | 15.750 20.000 16.000 25.000 20.000 |
6586016 | INSTL DEL ASSM (D-SW)SZ (BRF)GF1 (BI) | EA | 52.000 | 30.000 | 1 2 3 4 5 | 15.750 20.000 16.000 25.000 20.000 |
6586048 | INSTL OM ASSM (OM-2Z)(FLX)GND | EA | 98.000 | 50.000 | 1 2 3 4 5 | 47.250 50.000 47.000 50.000 62.000 |
6626004 | WK ZN PAV MRK NON-REMOV (W)4"(SLD) | LF | 82,264.000 | 0.100 | 1 2 3 4 5 | 0.150 0.100 0.110 0.120 0.170 |
6626034 | WK ZN PAV MRK NON-REMOV (Y)4"(SLD) | LF | 82,868.000 | 0.150 | 1 2 3 4 5 | 0.150 0.100 0.110 0.120 0.170 |
6626111 | WK ZN PAV MRK SHT TERM (TAB)TY Y-2 | EA | 6,223.000 | 1.000 | 1 2 3 4 5 | 1.000 0.600 1.400 1.000 2.000 |
6666303 | RE PM W/RET REQ TY I (W)4"(SLD)(100MIL) | LF | 41,504.000 | 0.450 | 1 2 3 4 5 | 0.270 0.320 0.400 0.400 0.410 |
6666312 | RE PM W/RET REQ TY I (Y)4"(BRK)(100MIL) | LF | 3,650.000 | 0.450 | 1 2 3 4 5 | 0.270 0.340 0.500 0.500 0.440 |
6666315 | RE PM W/RET REQ TY I (Y)4"(SLD)(100MIL) | LF | 150,963.000 | 0.450 | 1 2 3 4 5 | 0.270 0.320 0.400 0.400 0.410 |
6666342 | REF PROF PAV MRK TY I(W)4"(SLD)(100MIL) | LF | 116,588.000 | 0.750 | 1 2 3 4 5 | 0.580 0.580 0.650 0.650 0.760 |
6686076 | PREFAB PAV MRK TY C (W) (24") (SLD) | LF | 62.000 | 10.000 | 1 2 3 4 5 | 15.750 14.000 15.750 20.000 18.630 |
6726009 | REFL PAV MRKR TY II-A-A | EA | 2,057.000 | 3.000 | 1 2 3 4 5 | 3.150 3.200 3.400 3.500 4.140 |
60016002 | PORTABLE CHANGEABLE MESSAGE SIGN | EA | 2.000 | 10,000.000 | 1 2 3 4 5 | 5,000.000 10,000.000 20,000.000 10,000.000 23,000.000 |