AVERAGE LOW BID UNIT PRICE - MAINTENANCE - BEAUMONT DISTRICT

Last Update: Wednesday, November 29, 2017
ITEMS 500 2001 TO 560 6012
ItemsItemsBid Code Range
0104 - 0168
0247 - 0275
0310 - 0361
0400 - 0496
0500 - 0560
0618 - 0690
0712 - 0788
3003 - 3028
4014 - 4014
5049 - 5049
6000 - 6834
7010 - 7052
500 2001 - 560 6012
Item NoDescriptionUnitsNovember 30, 2017Twelve-Month-MovingUsage
QuantityAvg BidQuantityAvg Bid
500 2001MOBILIZATIONLS  3.00033,633.333333
500 6001MOBILIZATIONLS5.00049,649.8000040.00048,169.3000040
500 6033MOBILIZATION (CALLOUT)EA  294.000420.802728
500 6034MOBILIZATION (EMERGENCY)EA  20.0001,235.956006
502 2001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO  13.0002,535.384623
502 6001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO12.0005,520.91667127.0003,600.3464639
502 6015FURN ADDITIONAL TRUCKMOUNT ATTENUATORHR  18,675.00088.640362
502 6016FURN ADDITIONAL PORT CHANGABLE MESSAGEHR  600.0008.000001
502 6019BARR, SIGNS, TRAF HANDLE (TY-1)HR  12,900.000173.700001
502 6020BARR, SIGNS, TRAF HANDLE (TY-2)HR  3,900.000183.350001
502 6021BARR, SIGNS, TRAF HANDLE (TY-3)HR  1,150.000202.250001
502 6022BARR, SIGNS, TRAF HANDLE (TY-4)HR  450.000371.950001
502 6023BARR, SIGNS, TRAF HANDLE (TY-5)HR  450.000151.250001
502 6024FURNISH ADDITIONAL ARROW BOARDHR  900.0008.025002
506 2002ROCK FILTER DAMS (INSTALL) (TY 2)LF  800.00022.000001
506 2009ROCK FILTER DAMS (REMOVE)LF  800.0005.000001
506 2027BLADING WORK (EROSION & SEDM CONT)HR  2.000110.000001
506 2034TEMPORARY SEDIMENT CONTROL FENCELF  400.0003.000001
506 6002ROCK FILTER DAMS (INSTALL) (TY 2)LF180.00083.87000360.00083.870002
506 6003ROCK FILTER DAMS (INSTALL) (TY 3)LF  100.00040.000001
506 6011ROCK FILTER DAMS (REMOVE)LF180.00041.94000460.00034.126963
506 6030BACKHOE WORK (EROSION & SEDMT CONT)HR24.00091.9600048.00091.960002
506 6038TEMP SEDMT CONT FENCE (INSTALL)LF  50.0004.000001
506 6039TEMP SEDMT CONT FENCE (REMOVE)LF  50.0004.000001
506 6041BIODEG EROSN CONT LOGS (INSTL) (12")LF1,400.0007.162864,470.0006.869356
506 6042BIODEG EROSN CONT LOGS (INSTL) (18")LF  1,000.0004.500001
506 6043BIODEG EROSN CONT LOGS (REMOVE)LF1,400.0001.008575,470.0001.284107
510 6001ONE-WAY TRAF CONT (FLAGGER CONT)HR  6,750.00030.671332
510 6002ONE-WAY TRAF CONT (PILOT CAR)HR  2,250.00039.662002
529 6001CONC CURB (TY I)LF  200.00035.000001
529 6011CONC CURB (DOWEL)LF  585.00010.000001
530 2006INTERSECTIONS (SURF TREAT)SY  965.0005.100001
530 2057TURNOUTS (RAP)SY  479.00016.350001
530 6003INTERSECTIONS (SURF TREAT)SY3,510.0005.000007,020.0005.000002
530 6005DRIVEWAYS (ACP)SY  568.00028.000001
530 6008TURNOUTS (ACP)SY  389.00024.000001
530 6011INTRSCT, DRVWAYS, & TURNOUT (ACP)SY  722.00030.000001
531 6003CONC SIDEWALKS (6")SY  20.000113.000001
531 6004CURB RAMPS (TY 1)EA  6.0001,930.000001
531 6008CURB RAMPS (TY 5)EA  3.0002,682.000002
531 6010CURB RAMPS (TY 7)EA  4.0002,450.000001
533 6001RUMBLE STRIPS (SHOULDER)LF  53,002.0000.159412
533 6003RUMBLE STRIPS (SHOULDER) ASPHALTLF  3,200.0000.320001
533 6004RUMBLE STRIPS (CENTERLINE) ASPHALTLF  11,650.0000.190001
536 6002CONC MEDIANSY  10.000305.000001
540 2001MTL W-BEAM GD FEN (TIM POST)LF  150.00020.000001
540 2003MTL THRIE-BEAM GD FEN (TIM POST)LF  20.00015.000001
540 2005TERMINAL ANCHOR SECTIONEA  2.000250.000001
540 2007MTL W-BEAM GD FEN ADJUSTMENTLF  1.0009.000001
540 2008MTL THRIE-BEAM GD FEN ADJUSTMENTLF  1.0009.500001
540 2009TERMINAL ANCHOR SECTION ADJUSTMENTEA  1.000250.000001
540 2010TRANSITION ADJUSTMENTEA  1.000450.000001
540 2011MTL BEAM GD FEN TRANS (THRIE-BEAM)EA  1.0001,500.000001
540 2012MTL BEAM GD FEN TRANS (TL2)EA  1.0001,300.000001
540 2013MTL BEAM GD FEN TRANS (T101)EA  1.0001,100.000001
540 6001MTL W-BEAM GD FEN (TIM POST)LF880.00021.250002,635.00021.869077
540 6003MTL THRIE-BEAM GD FEN (TIM POST)LF  80.00028.125004
540 6005TERMINAL ANCHOR SECTIONEA  30.000100.333334
540 6006MTL BEAM GD FEN TRANS (THRIE-BEAM)EA  14.0002,021.428575
540 6007MTL BEAM GD FEN TRANS (TL2)EA  9.000955.555564
540 6008MTL BEAM GD FEN TRANS (T101)EA  8.0001,200.000004
540 6010MTL W-BEAM GD FEN ADJUSTMENTLF  502.0008.990044
540 6011MTL THRIE-BEAM GD FEN ADJUSTMENTLF  8.00025.250004
540 6012TERMINAL ANCHOR SECTION ADJUSTMENTEA  4.000100.250004
540 6013TRANSITION ADJUSTMENTEA  4.000125.000004
540 6016DOWNSTREAM ANCHOR TERMINAL SECTIONEA  5.0001,240.000005
540 6017MTL BM GD FEN (LONG SPAN SYSTEM)LF  50.00028.000004
542 2001REMOVING METAL BEAM GUARD FENCELF  100.0006.450001
542 2002REMOVING TERMINAL ANCHOR SECTIONEA  5.0001.000001
542 6001REMOVE METAL BEAM GUARD FENCELF880.0003.040006,750.0001.847477
542 6002REMOVE TERMINAL ANCHOR SECTIONEA3.000151.8000036.00086.411116
544 6001GUARDRAIL END TREATMENT (INSTALL)EA6.0002,428.7500019.0002,562.894745
545 6001CRASH CUSH ATTEN (INSTL)EA  4.00022,500.000004
545 6005CRASH CUSH ATTEN (REMOVE)EA  4.000750.000004
560 2015MAILBOX INSTALL-S(TWW-POST)TY 4 FND-TBEA  9.000194.000001
560 2016MAILBOX INSTALL-D(TWW-POST)TY2 FND-TBEA  5.000204.000001
560 2017MAILBOX INSTALL-M(TWW-POST)TY2 FND-TBEA  4.000500.000001
560 6011MAILBOX INSTALL-S (TWW-POST) TY 4EA  13.000220.000001
560 6012MAILBOX INSTALL-D (TWW-POST) TY 4EA  1.000370.000001