2004 English Special Specifications to Items 6000 - 6999 Lighting/Signing/Markings/Signals (Statewide & Districtwide, Current)


2004 English Special Specifications by Item (Statewide & Districtwide, Current)
Specification Information
Search For a Special Provision or Specification

SS6986  PDF  RTF  Longitudinal Prefabricated Pavement Markings (PPM) with Warranty - Furnish and place longitudinal PPM as shown on the plans. Provide a manufacturer’s warranty bond for a 6 year period. SP003---015 is required when this special specification is used. Replaces SS6951 . (Change Memo: de-27-07). Statewide Use. Special Provisions exist.
SS6834  PDF  RTF  Portable Changeable Message Sign - Furnish, operate, and maintain portable trailer mounted changeable message sign (PCMS) units. When measurement by the day is specified, a day shall be measured for each PCMS. Replaces SS 6038 beginning with the September 2007 letting. Replaces SS6038 . (Change Memo: de-14-07). Statewide Use. Special Provisions exist.
SS6473  PDF  RTF  Multipolymer Pavement Markings (MPM) - Provide MPM on pavement surfaces shown on the plans to meet the performance requirements of this Specification for: Color, durability, and retroreflectivity. Replaces SS 6279 beginning with the September 2006 letting. Replaces SS6279 . Statewide Use. Special Provisions exist.
SS6266  PDF  RTF  Video Imaging Vehicle Detection System - Install a Video Imaging Vehicle Detection System (VIVDS) that monitors vehicles on a roadway via processing of video images and provides detector outputs to a traffic controller or similar device. Replaces SS6087 . (Change Memo: de-35-05). Statewide Use. Special Provisions exist.
SS6195  PDF  RTF  Maintenance of Illumination Systems - Maintain, furnish, install, modify, repair, replace, or remove components of illumination systems. (Change Memo: de-25-05). Statewide Use. Special Provisions exist.
SS6153  PDF  RTF  Multipolymer Pavement Markings (MPM) with Warranty - Furnish and place MPM. Provide a manufacturer's warranty bond for longitudinal lines for 3 years. The Dept will allow a Contractor provided warranty bond in lieu of the manufacturer's bond.This warranty spec is only to be used on pure traffic projects. SP003---015 is required when this special specification is used. Statewide Use. Special Provisions exist.
SS6152  PDF  RTF  Raised Pavement Markers (RPMs) with Warranty - Furnish and place RPMs. Provide a manufacturer's warranty bond for RPMs for a 1 year period. The Department will allow a Contractor provided warranty bond in lieu of the manufacturer's bond. This warranty spec is only to be used on pure traffic projects. SP003---015 is required when this special specification is used. (Change Memo: de-21-05). Statewide Use.
SS6122  PDF  RTF  Relocate High Mast Lighting - Relocate high mast lighting. (Change Memo: de-18-05). Statewide Use.
SS6119  PDF  RTF  Relocate or Remove Pedestal Pole Assemblies - Remove and relocate existing pedestal pole assemblies. Statewide Use.
SS6055  PDF  RTF  In-Lane or Transverse Rumble Strip - Provides for a material producers list for rumble strips. (Change Memo: de-80-04). Statewide Use.
SS6043  PDF  RTF  Microwave Presence Vehicle Detector - Furnish and install microwave presence vehicle detector unit. (Change Memo: de-75-04). Statewide Use.
SS6042  PDF  RTF  Solar-Powered Navigational and Aircraft Obstruction Lighting System - Furnish and install solar powered navigation and aviation lighting system; remove existing navigation and aviation lighting systems. (Change Memo: de-72-04). Statewide Use.
SS6041  PDF  RTF  Internally Lighted Street Name Sign Assemblies - Furnish and install internally lighted street name sign assemblies. (Change Memo: de-71-04). Statewide Use.
SS6040  PDF  RTF  Horizontal Sign Light - Furnish and install fluorescent sign lights for traffic signals. (Change Memo: de-70-04). Statewide Use.
SS6027  PDF  RTF  Lane Control Signal Equipment - Furnish and install Lane Control Signal (LCS) equipment. (Change Memo: de-65-04). Statewide Use. Special Provisions exist.
SS6026  PDF  RTF  National Transportation Communications for ITS Protocol for Dynamic Message Signs - Provide Dynamic Message Signs (DMS) software that complies with the National Transportation Communications for ITS Protocol (NTCIP). Statewide Use.
SS6025  PDF  RTF  CCTV Field Equipment - Furnish and install closed circuit television (CCTV) field equipment. Statewide Use. Special Provisions exist.
SS6024  PDF  RTF  Fiber Optic Dynamic Message Sign System - Furnish and install fiber optic dynamic message sign (DMS) systems with nominal 8-in., 12-in., and 18-in. characters. (Change Memo: de-45-04). Statewide Use. Special Provisions exist.
SS6022  PDF  RTF  Rack Mounted Electronic Equipment Cabinet - Furnish, install, and test rack mounted electronic equipment cabinets. (Change Memo: de-48-04). Statewide Use.
SS6020  PDF  RTF  Surveillance System Loop Detector - Furnish and install loop detector wire, loop detector cable, conduit, sealant, and preformed conduit encased loop detectors. Statewide Use.
SS6019  PDF  RTF  Local Control Unit - Furnish and install local control units. Statewide Use. Special Provisions exist.
SS6018  PDF  RTF  Limited Distance Modem - Furnish and install Limited Distance Modems (LDM). Statewide Use. Special Provisions exist.
SS6017  PDF  RTF  Local Control Unit (LCU) Interface to Field Equipment - Furnish and install local control unit (LCU) interface to field equipment. (Change Memo: de-56-04). Statewide Use.
SS6016  PDF  RTF  ITS Field Equipment Cabinet - Furnish, install, and test equipment cabinets. Statewide Use. Special Provisions exist.
SS6015  PDF  RTF  ISDN Compressed Video Equipment - Furnish and install Integrated Services Digital Network (ISDN) Compressed Video Equipment (CVE). (Change Memo: de-44-04). Statewide Use.
SS6014  PDF  RTF  Fiber Optic Cable - Furnish, install, splice, field terminate, and test the fiber optic cables. Statewide Use. Special Provisions exist.
SS6013  PDF  RTF  Electronic Components - Use electronic components to manufacture electronic equipment. Statewide Use. Special Provisions exist.
SS6012  PDF  RTF  Dial-Up Modem - Furnish and install stand-alone Dial-Up Modem. (Change Memo: de-44-04). Statewide Use.
SS6011  PDF  RTF  Testing, Training, Documentation, Final Acceptance, and Warranty - Perform or furnish testing, training, documentation, final acceptance, and warranty on the applicable equipment or systems. Statewide Use. Special Provisions exist.
SS6010  PDF  RTF  Communication Cable - Furnish, install, and test communication cable. Statewide Use.
SS6009  PDF  RTF  ITS System Support Equipment - Furnish, assemble, fabricate, or install ITS system support equipment. (Change Memo: de-43-04). Statewide Use.
SS6008  PDF  RTF  Shifting or Removing Existing Overhead Signs - Shift or remove existing overhead sign panels. Statewide Use.
SS6007  PDF  RTF  Removing Traffic Signals - Remove, store, and salvage traffic signals. Statewide Use. Special Provisions exist.
SS6006  PDF  RTF  Spread Spectrum Radios for Traffic Signals - Furnish and install spread spectrum radios. Statewide Use. Special Provisions exist.
SS6005  PDF  RTF  Uninterruptible Power Supply - Furnish and install an Uninterruptible Power Supply (UPS). (Change Memo: de-43-04). Statewide Use. Special Provisions exist.
SS6004  PDF  RTF  Digital Card Rack Inductive Loop Detector Assembly - Furnish and install a digital card rack inductive loop detector assemblies. (Change Memo: de-44-04). Statewide Use. Special Provisions exist.

  DALLAS - DISTRICT 18
SS6949  PDF  RTF  Install or Replace VIVDS Camera Assembly and VIVDS Communication Cable - Install or replace Video Imaging Vehicle Detection System (VIVDS) camera assemblies and VIVDS communication cable at existing traffic signal location(s). Districtwide Use. Special Provisions exist.

  PARIS - DISTRICT 1
SS6949  PDF  RTF  Install or Replace VIVDS Camera Assembly and VIVDS Communication Cable - Install or replace Video Imaging Vehicle Detection System (VIVDS) camera assemblies and VIVDS communication cable at existing traffic signal location(s). Districtwide Use. Special Provisions exist.

  LUBBOCK - DISTRICT 5
SS6948  PDF  RTF  Refurbish Raised Reflective Pavement Markers - Remove and replace the reflective faces of Plowable Reflectorized Pavement Markers Type I-A, Type I-C, Type I-R, Type II-A-A, Type II-A-R, and Type II-C-R for Item 672, ''Raised Pavement Markers''. Districtwide Use.

  HOUSTON - DISTRICT 12
SS6920  PDF  RTF  CCTV Field Equipment - Furnish and install Closed Circuit Television (CCTV) field equipment in designated field locations and equipment cabinets as shown on the plans. Districtwide Use. Special Provisions exist.
SS6919  PDF  RTF  Communications Hub Building - Furnish and install Communications Hub Buildings as shown on the plans. Districtwide Use.
SS6623  PDF  RTF  Multi-Duct Conduit System - Furnish and place a Multi-Duct Conduit (MDC) system that is suitable for installation in an outdoor underground environment including constant immersion in water, and/or hung from a bridge without any degradation in the conduit. Districtwide Use.

  DALLAS - DISTRICT 18
SS6608  PDF  RTF  Linear Delineation System - Furnish and place Linear Delineation System (LDS) panels and remove LDS panels. Districtwide Use.

  HOUSTON - DISTRICT 12
SS6478  PDF  RTF  Intelligent Transportation System (ITS) Controller Cabinet Assembly - Furnish Intelligent Transportation System (ITS) Cabinet for use with Type 2070 Advanced Transportation Controller (ATC). Districtwide Use. Special Provisions exist.
SS6477  PDF  RTF  Model 2070 Controller Unit - Furnish Type 2070 Advanced Transportation Controller (ATC) unit. Districtwide Use.

  CORPUS CHRISTI - DISTRICT 16
SS6422  PDF  RTF  Portable Changeable Message Sign - Furnish portable trailer mounted changeable message sign (PCMS) units during roadway construction for traffic handling in work areas. Districtwide Use.

  PARIS - DISTRICT 1
SS6380  PDF  RTF  Relocate Electrical Service Assemblies - Relocate existing electrical service assemblies. Districtwide Use.

  DALLAS - DISTRICT 18
SS6278  PDF  RTF  Fiber Optic RS-232 Data Modem - Furnish and install Fiber Optic RS-232 Data Modem (FO-MODEM) in locations, as shown on the plans, and as detailed in the Special Specifications. Districtwide Use.

  HOUSTON - DISTRICT 12
SS6278  PDF  RTF  Fiber Optic RS-232 Data Modem - Furnish and install Fiber Optic RS-232 Data Modem (FO-MODEM) in locations, as shown on the plans, and as detailed in the Special Specifications. Districtwide Use.

  DALLAS - DISTRICT 18
SS6277  PDF  RTF  Multi-Duct Conduit System - Furnish conduit of the type and sizes shown on the plans and as directed. Ensure the conduit system is suitable for installation in an outdoor underground environment. Districtwide Use.
SS6233  PDF  RTF  ISDN Network Termination Unit - This Item will govern for the furnishing and installation of stand-alone ISDN Network Termination Units (INTU) in the locations shown on the plans. Districtwide Use.
SS6232  PDF  RTF  Remove Ground Box - Remove ground box, as shown on the plans, or as directed. Districtwide Use.
SS6229  PDF  RTF  Camera Pole Structure with Cabinet - This Item will govern the design, fabrication, delivery, and installation of camera pole structures with cabinets as shown on the plans. Districtwide Use. Special Provisions exist.
SS6228  PDF  RTF  Integration of LED Dynamic Message Signs - This Item will govern for the integration of the Contractor installed LED Dynamic Message Signs (DMS) system with existing LED DMS equipment and communications network. Districtwide Use.
SS6150  PDF  RTF  Fiber Communications HUB Building Replacement - Govern for the replacement of a Fiber Communications HUB Building. Districtwide Use.
SS6118  PDF  RTF  Illumination - Maintenance, repair and/or replacement of the various appurtenances related to existing illumination assemblies. Replaces SS6031 . Districtwide Use.

  WACO - DISTRICT 9
SS6079  PDF  RTF  LED Changeable Speed Limit Sign - Furnish, maintain, and operate LED Changeable Speed Limit (CSL) sign(s). Districtwide Use.

  HOUSTON - DISTRICT 12
SS6078  PDF  RTF  Portable Changeable Message Sign - Furnish, operate, and maintain portable trailer-mounted changeable message sign (PCMS) units. Districtwide Use.
SS6062  PDF  RTF  Portable Changeable Message Signs - Provide during construction operations, portable changeable message signs meeting the requirements of this specification for use in traffic control during the work and maintain and operate the units during the work. Districtwide Use.

2004 English Special Specifications by Item (Statewide & Districtwide, Current)
Specification Information
Search For a Special Provision or Specification